My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 4:47:24 PM
Creation date
6/23/2020 6:59:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2002-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
404
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
01/08/2004 08:23 20946834 <br />16 FIFTH FLOOR PAGE 06 <br />Note: Enhanced Leak Detection (ELD) must be performed prior to the final inspection. A <br />separate permit application is required to install ELD. <br />❑ Complete to scale As -Built Plans <br />❑ Complete Monitoring and Response Plan <br />❑ UPCF Underground Storage Tanks - Installation Certificate of Compliance (one form per <br />tank) <br />❑ Completed Underground Storage Tank Certification of Financial Responsibility form along <br />with any required attachments <br />❑ Passing Line Leak Detector Test Results <br />❑ Passing Line, Tightness Test Results (Required if the UST system does nor satisfy the <br />California Code of Regulations 2636(g) for automatic pump shut-off.) <br />❑ Passing Enhanced Leak Detection Results <br />MEMILMON I We <br />Mote: A representative from the San Joaquin County Environmental Health Department <br />must witness all activities described below. <br />❑ Tank holiday test (for fiberglass -coated steel tanks) performed prior -to installation hn <br />excavation <br />❑ Inspection of tank vacuum gauge (if applicable) prior to plactnnent in excavation <br />Tank soap test (for fiberglass tanks) performed prior to installation in excavation <br />❑ Verification of tank set and anchorage in excavation <br />❑ Primary piping including product piping, vapor recovery and vent line piping soap and <br />pressure test <br />F] Secondary piping including product piping, vapor recovery and vent line piping soap alld <br />pressure test <br />❑ 24 -Hour secondary containment lake test on sumps and under -dispenser contaimiaent <br />❑ Visual inspection of piping to ensure proper slope prior to covering <br />❑ Overfill performance test <br />❑ Prior to receiving fuel, a complete functional test of tank and piping monitoriqg systern(s) <br />including overfill prevention <br />❑ Final inspection and demonstration of automatic shut down (if applicable,). <br />-5- <br />