My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2023 3:02:54 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2016-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FA0015274 pno522448 ouoo 03/29/2017 <br />s*oux-01 Rev. 09/22/16 page 1 of Underground Storage Tank Program mn <br />San Joaquin County 'Wr <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sffigov.ocgjabLd <br />0 2p i )0117 <br />Facility Name: <br />SHELL 1-5 <br />Facility Phone: <br />(209) 939-0961 <br />Date: <br />March 29, 2017 <br />Facility Address: <br />717 W EIGHTH ST, STOCKTON, CA 95206 <br />CERS ID: <br />10184915 <br />Inspection Contact: <br />Joe Dangtran <br />Title: <br />Owner <br />Phone: <br />(209) 939-0961 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2371 - LIST FACILITY - 1702 COMPLIANT <br />Consent For: <br />N Inspection N Photos Z Sample <br />I Consent Given By: <br />Joe Dangtran, Owner <br />Service Technician Onsitec <br />Jeff Conger <br />Exp. Date: <br />02/09/2019 <br />Designated Operator: <br />Douglas Nunn <br />Exp. Date: <br />07/27/2017 <br />Service Technician Manufacturer's Training <br />Veeder Root, 01/27/19; VMI, 09/29/18 <br />CCR California Code of Regulations HSC Health and Safety Code CFR = Code of Federal Regulations <br />V Violation R =Repeat violation COS= Corrected on site during inspection <br />Ulm 00 <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />Li V <br />o R <br />Li COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />m V <br />m R <br />c COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />m V <br />a R <br />c COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />n V <br />ii R <br />Ei COS <br />106 <br />C R 2632(d)(2) <br />Failed to have an approved UST response plan <br />Li V <br />Li R <br />Li COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />m V <br />Li R <br />Li COS <br />108 <br />CCR 2637ft 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />o V <br />c R <br />ii COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />o V <br />o R <br />o COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />o V <br />Ei R <br />o COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />o V <br />o R <br />o COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />o V <br />o R <br />Ei COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />o V <br />Lj R <br />o COS <br />114 <br />CCR 2636(� <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />Ej V <br />o R <br />Li COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />o V <br />o R <br />o COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />o V <br />o R <br />o COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />Li V <br />o R <br />o COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />ii V <br />o R <br />o COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />ii V <br />o R <br />o COS <br />120 <br />j CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />o V <br />Ei R <br />o COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />Li V <br />Li R <br />o COS <br />122 <br />CCR 26310) <br />Failure to submit UST system component statement of compatibility for substance stored <br />c V <br />o R <br />c COS <br />201 <br />CCR 2712(b) <br />Failed to maintain alarm logs and/or records of follow up actions <br />Li V <br />Ei R c COS <br />202 <br />C R 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />Ei V <br />Ei R <br />ii COS <br />203 <br />CCR 2712(b) <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />o V <br />o R <br />Li COS <br />FA0015274 pno522448 ouoo 03/29/2017 <br />s*oux-01 Rev. 09/22/16 page 1 of Underground Storage Tank Program mn <br />
The URL can be used to link to this page
Your browser does not support the video tag.