My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2023 3:02:54 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2016-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P1'e of —8- <br />I <br />Facility ie Nnt E Lij e�d W;th F;11 Ri_qnr r.nntainmeni Sumns 11 1 <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />Test Method Developed By: Sump Manufacturer X Industry Standard Professional E� gineer <br />Other (Specify) <br />Test Method Used: Pressure Vacuum X Hydrostatic <br />Other (Specify) <br />Test Equipment Used: Caldwell Level Indicator Equipment Resolution:.00 <br />Fill Sump #UnI <br />FM Snap #Prem ern Fill Sump #Diesel <br />Fill lump# <br />Sump Diameter: <br />42 <br />42 42 <br />Sump Depth: <br />59 <br />58 59 <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />0 <br />0 0 <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />32 <br />30 30 <br />A—hil <br />Condition of sump prior to <br />testing: <br />Clean <br />Clean Clean <br />Portion of Sump Tested <br />20 <br />20 20 <br />M A <br />Sump Material: <br />Fiberglass <br />Fiberglass Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />15mins <br />15mins 15mins <br />Test Start Time: <br />30mins <br />30mins 30mins <br />Initial Reading (RI): <br />first circle <br />first circle first circle <br />End Time- <br />Omins <br />Omins Omins <br />-Test <br />Final Reading (RF): <br />no change <br />no change no chan e <br />Test Duration: <br />30mins <br />30mins 30mins <br />Change in Reading (RF-Ro: <br />0 <br />0 0 <br />Threshold or Criteria: <br />.005/30mins <br />.005/30mins .005/30mins <br />-Pass/Fail <br />Jest Result: <br />x i;; -s Ean <br />xPass Fail xPass Fail <br />Pass Fail <br />Is there a sensor in the sump? <br />X Yes No <br />X Yes No XYes No <br />1Yes No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />XYes No NA <br />XYes No NA XYes No NA <br />s No NA <br />Was sensor removed for testing? <br />X Yes No NA <br />X Yes No NA XYes No NA <br />No NA <br />Was sensor properly replaced and <br />,nal after testin 9 <br />Yes No XNA <br />Yes No X NA Yes No X NA <br />No NA <br />
The URL can be used to link to this page
Your browser does not support the video tag.