My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2023 3:02:54 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2016-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical / Electronic Leak Detector Test <br /> Site: Test Company <br /> Shell 1-5 Pinnacle Fuel Compliance <br /> 717 W. Eighth St. P.O. Box 32849 <br /> Stockton, Ca. 95206 San Jose, CA 95152 <br /> (408)206-9840 <br /> Test Information <br /> 1 2 3 4 <br /> Product #1-Reg #2-Prem #3-Diesel <br /> Manufacturer Veederoot VMI VMI <br /> Model FX1 V LD2000 LD2000 <br /> Full Operating Pressure (psi) 37 36 40 <br /> Line Bleed Back (ml) 125 999 999 <br /> Trip Time (sec) 2 9 <br /> Metering Pressure 12 21 26 <br /> F/E Holding Pressure (psi) 27 37 34 <br /> Test Leak Rate (ml/min)(gph) 189 189 189 <br /> PASS or FAIL PASS No Test PASS <br /> This form certifies that the annual line leak detector tests were performed at the above referenced <br /> facility according to the equipment manufacturers procedures and limitations and the results as listed <br /> are to my knowledge true and correct.The mechanical/electronic line leak detector test pass/fail is <br /> determined using a low flow rate threshold trip rate of 3 gph at 10psi. <br /> Note that due to the damage to dispenser 11-12 there is air trapped in the <br /> dispenser which could not be purged. Could not achieve a test until repaired. <br /> Tester: Jeff Conger Date: 3/8/2018 <br /> L <br /> Signature: -- Lic# 1081782 UT rzxxAcz.E <br /> Mechanical/Electronic Leak Detector Test <br />
The URL can be used to link to this page
Your browser does not support the video tag.