Laserfiche WebLink
S A KJOAQU IN Environmetal Health Department <br /> COU NTY <br /> here. <br /> ME -W <br /> F—IffloNINE !"-NT11W <br /> Facility Name: Facility Phone: Date: <br /> SHELL 1-5 (209) 939-0961 March 08, 2018 <br /> Facility Address: CERS ID: <br /> 717 W EIGHTH ST, STOCKTON, CA 95206 10184915 <br /> Inspection Contact: Title: Phone: <br /> Joe Dangtran Owner (408) 666-0009 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION - Operating Permit 12371 - LIST FACILITY- 1702 COMPLIANT <br /> Consent For: I Consent Given By: <br /> Z Inspection Z Photos Z Sam ples I Joe Dangtran, Owner <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Jeff Conger 02/09/2019 Douglas Nunn 07/25/2019 <br /> Service Technician Manufacturer's Training <br /> VMI, 09/29/18; Veeder Root, 01/27/19 <br /> CCR California Code of Regulations 14SC=Health and Safety Code CFR Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> W <br /> MF fug 1931 1pgwjq- 9 <br /> g, <br /> t <br /> obtain a valid permit to operate from the EHD including but not limited to unpaid fees <br /> 101 HSCM25284� m V c R o COS1 <br /> 102 1 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system c V Ei R o COS <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted Lj V ii R D COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current Ei V ii R o COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan m V m R m COS <br /> 2634(d) <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan c V o R Ei COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed c V ci R c COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V Ei R Ei COS <br /> 109 CCR 2637 Failed to test secondary containment o V o R Ei COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ii V Ei R Ei COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ii V Ei R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually Li V o R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days Ei V Ei R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down Ei V o R ii COS <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change w/in 30 days c V u R u COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V D R c COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ii V Li R Li COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ii V Li R Li COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented Ei V ii R Ei COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification Li V o R 13 COS <br /> 1121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report Lj V o R o COS <br /> 122 CCR 26310) Failure to submit and maintain UST system component statement of compatibility for substance stored Li V o R o COS <br /> 61p, 0 - <br /> Iffiffim <br /> IN` <br /> 19, <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records o V o=Ro COS <br /> S <br /> FA0015274 PRO522448 SCO01 03/08/2018 <br /> EHD 23-01 Rev.10/31/2017 Page I of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-34201 F 209 464-0138 1 www.sjcehd.com <br />