COMPLIANCE INFO_2007-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2007-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:00:07 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2007-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
438
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK SYSTEM <br />Jilll 1,300161 ii <br />Facility Name: Shell 1-5 <br />MONITORING PANEL / ALARM HISTORY <br />Inspection Date: VIC-Anuary 18, 2012 <br />Facility Address: 717 W. 8h- St.City: <br />Is the monitoring system powered on and in roper operating mode? <br />Stockton <br />Name of Designated UST Operator Conducting Inspection: <br />Robert Barnhart <br />InternationalCouncil Certification No.: P52540 -u -C <br />1 -0 <br />3. <br />Expiration Date: 1/28/2014 <br />1 <br />Signature, <br />--j <br />Phone: (209) 604-9336 ext. <br />01 <br />N/A = Nnt A ..16. hi. <br />Item <br />MONITORING PANEL / ALARM HISTORY <br />Yes No N/A <br />1. <br />Is the monitoring system powered on and in roper operating mode? <br />2. <br />Is the monitoring system not currently showing any leak alarms? <br />3. <br />Is the Alarm History Report/log for the previous month available, and has it been reviewed by the <br />Designated UST Operator? (Attach a copy ofthe alarm history reportllog to this ins pectionform) <br />alarm4. Has each for the previous month been responded to appropriately? <br />ID 13 <br />W - <br />UST SYSTEM INSPECTION <br />5. <br />Are tank -top containment sumps free of water, debris, and hazardous substance? Note: If the answer to Item 4 was "Yes, skip <br />to Item 6. Sumps where an alarm has occurred in the past month must be inspected if a qualified service technician has not responded to, and <br />properly addressed, the cause of the alarm. Documentation vera to appropriate service should he attached to this re ort. <br />Yes I No <br />Su <br />Sum Location: <br />Yes Nom <br />Li <br />s <br />Sum R Location:: <br />Sump Location: 101 <br />Sump Location: <br />6. <br />Are Till buckets (containment -e of water, debris, and hazardous substance? <br />Yes No N/A <br />Yes No <br />NIA <br />Tank I ID — Regular ❑ Tank 4 ID — <br />El 0 <br />El <br />Tank 2 ID — Supreme Tank 5 ID — <br />Tank 3 ID — Diesel I Z 10 1 [:1 Tank 6 ID — <br />7. <br />Are under -dispenser containment areas free of water, debris, and hazardous substance? <br />Yes No N/A. <br />Yes No N/A <br />Dispenser — 1/2 ❑ Dispenser — 9/10 <br />Dispenser — 3/4 LJ Dispense — 11/12 <br />El 0 <br />Dispenser — 5/6 Lj Dispense — 13/14 <br />49 <br />FM 0 El <br />Dispenser — 7/8 ❑Lj I Dispenser — 15/16 <br />8. <br />Leak detection is properly located within under -dispenser containment. <br />Yes <br />I No N/A <br />Yes No N/A <br />Dispenser — 1/2 <br />1 El Dispense —9/10 <br />El 1:1 <br />Dispenser — 3/4 <br />El -Lj Dispense —11/12 <br />Dispenser — 5/6 <br />Dispense — 13/14 <br />Dispenser — 7/8 <br />1 El ET Dispenser , —15/16 0 1 ED -1 <br />7 <br />PAPERWORK INSPECTION Yes No <br />Date Done <br />9. <br />Monitoring System Certification was completed within. the past 12 months? M <br />4/19/2011 <br />10. <br />Line Leak Detectors were tested/certified within the past 12 months? <br />4/19/2011 <br />11. <br />Spill bucket (containment structure) testing completed within the past 12 months? 1 E:1 Lj <br />4/19/2011 <br />_12. <br />Line tightness testing completed within the required time frame? <br />13. 1 <br />Secondary containment tests completed within the required time frame? <br />4/21/2009 <br />-14. <br />Enhanced Leak Detection completed within the reguired time frame? Li I Li N <br />1 <br />15. <br />Other required testing/maintenance was completed within required time frame? (List test/maintenance items below.) <br />- <br />Describe Test/Maintenance: Air Quality I Z El E <br />2/3/2011 <br />Describe Test/Maintenance: <br />I I <br />FACILITY EMPLOYEE TRAINING <br />Yesl No 1 <br />16. <br />Have all facility empl—ees received the required on-t-hejob training within the 2ast year? <br />17. <br />Have I fhciliemployees hired within ast 30 q!XIreceived ,the .required on:the-'ob training.? <br />F-1 I I I 15ZI <br />Note: Expiain any --NO- answers in the"Comments" section on the following page. Those issues require corrective �action from <br />the UST owner/operator. <br />UN -057 - 1/2 www.unidoes.org 9/26105 <br />