My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2007-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:00:07 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2007-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
438
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY 0 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjaov.org/ehd <br />CONTINUATION FORM <br />Page: 4 of 5 <br />OFFICIAL INSPECTION REPORT <br />Date: 03/04/13 <br />Facility Address: Shell 1-5; 717 West Eighth Street, Stockton <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLASS 11, or MINOR -Notice to Comply) <br />204. The designated operator failed to check and note the correct test dates for the monitoring <br />certification, leak detector, and spill container tests on the March 2012 through February 2013 <br />designated operator monthly inspection reports. These reports listed the tests as March 27, 2012. It <br />should have been listed as March 28, 2012. During the monthly inspection, the designated operator shall <br />check that all required testing and maintenance for the UST system have been completed and document <br />the dates they were done. Ensure that designated operators performing monthly inspections at this <br />facility are including all of the required information on the reports. <br />204. The designated operator failed to verify that all employees have been trained during the January <br />30, 2012 monthly inspection. During the monthly inspection, the designated operator shall verify that all <br />facility employees have been trained. Ensure that designated operators performing monthly inspections <br />at this facility are including all of the required information on the reports. <br />303. The following sensors were at the bottom of the sump approximately two to six inches above the <br />lowest point of the sump, part way up the sump saddle, and not located to detect a leak at the earliest <br />opportunity: 87 STP Sump sensor 6 inches, 87 Fill Sump sensor 2 inches, Diesel STP Sump sensor 6 <br />inches, Diesel Fill Sump sensor 3 inches, 91 STP Sump sensor 6 inches, and 91 Fill Sump sensor 2 <br />inches. Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible <br />opportunity. During the inspection, the technician relocated these sensors to the lowest point of the <br />sumps. Note: Owner states that previous inspector was ok with the location of the sensors in the straight <br />up position during the last monitoring system certification even though the lip of the sump prevented the <br />sensor from reaching the lowest point of the sump. <br />403. The STP and vent sumps did not have gaskets nor constructed to keep the UST system product <br />tight. Secondary containment shall be impervious to the liquid and vapor of the substance contained and <br />constructed to prevent structural weakening as a result of contact with any hazardous substances <br />released from the primary containment. Immediately contact a properly licensed, trained, and certified <br />contractor to make repairs to the UST system under permit and inspection of the EHD. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TqWINSP <br />NY TIME T EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: <br />Aris Cacapit (209) 468-3453 '- <br />Received By: <br />me <br />Title: <br />EHD 23-02-003 Rev 04/19/12 9f CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.