Laserfiche WebLink
r <br />0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaoy.org/ehd/unitiii.html <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Shell 1-5 Facility Insp <br />717 West Eighth Street, Stockton Dateection <br />Name: Address: Mar 28, 2012 <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal Re ulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />ssuriz ` u <br />702 CCR 2643(e) Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />999 Other: See attached "Continuation — Official Inspection Report' for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />UST inspection: Routine and Annual Monitoring System Certification <br />Revision of UST Official Inspection Report on April 4, 2012 <br />Revising violation # 310 to # 404. UST system was installed between 07/01/2003 - 06/30/2004. <br />404. Less than one inch of liquid was observed in the vent sump . If water could enter into the <br />secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br />Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous waste <br />regulations, and manage it accordingly. Ensure that the vent sump is maintained free of liquid. <br />- corrected on site. technician removed liquid into hazardous waste drum <br />314. The enunicator used as part of the overfill prevention system is not currently functional on the <br />audio/visual alarm on the UST. The audio was replaced and retested during the inspection. <br />- corrected on site. technician replaced audio. <br />Notes- <br />- Provided free training schedule. Recommended courses for employees: Hazardous & Universal waste <br />management. Underground storage tank for owners/ operators. call to sign up. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Title: <br />EHD 23-02 Rev 09/01/1111 Page 3 UST INSPECTION REPORT <br />