My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2007-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:00:07 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2007-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
438
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T 3: D I ESEL <br />PRODUCT CODE 3 <br />THERMAL COEFF :.000450 <br />OUTPUT RELAY SETUP <br />- - - - - - - - - - - - <br />LIQUID SENSOR SETUP <br />TANK DIAMETER 118-00 <br />- - - - - - - - - - - - <br />TANK PROFILE 4 PTS <br />R 1:REGULAR <br />FULL VOL 11849 <br />L I:REGULAR ANNULAR <br />TYPE: <br />88.5 INCH VOL 9730 <br />59.0 INCH VOL 6008 <br />DUAL POINT HYDROSTATICSTANDARD <br />CATEGORY : ANNULAR SPACE <br />NORMALLY CLOSED <br />29.5 INCH VOL 2257 <br />LIQUID SENSOR ALMS <br />FLOAT SIZE: 4.0 IN. <br />L 2:VPOWERDIESEL ANNULAR <br />L 3:FUEL ALARML10:FUEL ALARM <br />WATER WARNING 1.0 <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />LII:FUEL ALARM <br />HIGH WATER LIMIT: 2.0 <br />L12:FUEL ALARM <br />L13:FUEL ALARM <br />MAX OR LABEL VOL: 11849 <br />L14:FUEL ALARM <br />OVERFILL LIMIT 90% <br />L 3:REGULAR STP SUMP <br />L15:FUEL ALARML <br />10664 <br />HIGH PRODUCT 95% <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />3:SENSOR OUT ALARM <br />LIO:SENSOR OUT ALARM <br />11256 <br />LII:SENSOR OUT ALARM <br />DELIVERY LIMIT 9% <br />L12:SENSOR OUT ALARM <br />1172 <br />L 4:V -POWER STP SUMP <br />L13:SENSOR OUT ALARM <br />L14:SENSOR <br />LOW PRODUCT 800 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />OUT ALARML15:SENSOR OUT ALARM <br />LEAK ALARM LIMIT: 99 <br />L 3:SHORT ALARM <br />SUDDEN LOSS LIMIT: 99 <br />L10:SHORT ALARM <br />TANK TILT 1.62 <br />L 5:DIESEL STP SUMP <br />LII:SHORT ALARM <br />L12:SHORT <br />ROBE OFFSET 0.00 <br />PROBE <br />TRI-STATE (SINGLE FLOAT) <br />ALARM <br />L13:SHORT ALARML14:SHORT <br />CATEGORY : STP SUMP <br />ALARM <br />SIPHON MANIFOLDED TANKS <br />L15:SHORT ALARM <br />TO: NONE <br />LINE MANIFOLDED TANKS <br />L 6:REGULAR FILL <br />TRI-STATE (SINGLE FLOAT) <br />R 2: <br />V -POWER <br />TO: NONE <br />CATEGORY : PIPING SUMP <br />TYPE: <br />NORMALLY CLOSED <br />LEAK MIN PERIODIC: 01/6 <br />L 7:V -POWER FILL <br />0 <br />TRI-STATE (SINGLE FLOAT) <br />LIQUID SENSOR ALMS <br />LEAK MIN ANNUAL 0% <br />CATEGORY : PIPING SUMP <br />L 4:FUEL ALARM <br />0 <br />LIO:FUEL ALARM <br />L 8:DIESEL FILL <br />Lll:FUEL ALARML12:FUEL ALARM <br />PERIODIC TEST TYPE <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : PIPING SUMP <br />L13:FUEL ALARM <br />STANDARD <br />L14:FUEL ALARM <br />L15:FUEL ALARM <br />ANNUAL TEST FAIL <br />L 9:VAPOR VENT <br />L 4:SENSOR OUT ALARML10:SENSOR <br />ALARM DISABLED <br />TRI-STATE (SINGLE FLOAT) <br />OUT ALARM <br />Lll:SENsOR <br />PERIODIC TEST FAIL <br />CATEGORY : PIPING SUMP <br />OUT ALARM <br />L12:SENSOR OUT ALARM <br />ALARM DISABLED <br />L13:SENSOR OUT ALARM <br />L10:DISPENSER 1-2 <br />L14:SENSOR OUT ALARM <br />GROSS TEST FAIL <br />TRI-STATE (SINGLE FLOAT) <br />L15:SENSOR OUT ALARML <br />ALARM DISABLED <br />CATEGORY : DISPENSER PAN <br />4:SHORT ALARM <br />LIO:SHORT ALARM <br />ANN TEST AVERAGING: OFF <br />Lll:SHORT ALARM <br />PER TEST AVERAGING: OFF <br />L12:SHORT ALARM <br />TANK TEST NOTIFY: OFF <br />Lll:DISPENSER 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />L13:SHORT ALARM <br />L14:SHORT ALARM <br />CATEGORY : DISPENSER PAN <br />L15:SHORT ALARM <br />TNK TST SIPHON BREAKOFF <br />R 3:DIESEL <br />DELIVERY DELAY 3 MIN <br />TYPE: <br />PUMP THRESHOLD 10.00% <br />L12:DISPENSER 5-6 <br />STANDARD <br />NORMALLY <br />TRI-STATE (SINGLE FLOAT) <br />CLOSED <br />CATEGORY : DISPENSER PAN <br />LIQUID SENSOR ALMS <br />L 5:FUEL ALARM <br />LEAK TEST METHOD <br />- - - <br />L13:DISPENSER 7-8 <br />LII:FUEL ALARM <br />- - - - - - - - - <br />TEST ON DATE : ALL TANK <br />TRI-STATE (SINGLE FLOAT) <br />L15:FUEL ALARM <br />L 5:SENSOR OUT ALARM <br />NOV 10, 2003 <br />CATEGORY : DISPENSER PAN <br />LII:SENSOR OUT ALARM <br />START TIME : DISABLED <br />L15:SENSOR OUT ALARM <br />TEST RATE :0.20 GAL/HR <br />L 5:SHORT ALARM <br />DURATION 2 HOURS <br />L14:DISPENSER 9-10 <br />LII:SHORT ALARM <br />TST EARLY STOP:DISABLED <br />TRI-STATE (SINGLE FLOAT) <br />L15:SHORT ALARM <br />CATEGORY : DISPENSER PAN <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />L15:DISPENSER 11-12 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.