My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2007-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:00:07 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2007-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
438
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring_ system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Shell 1-5 <br />Bldg. No.: <br />Site Address: 717 W. Eighth St. City: Stockton Zip: 95206 <br />Facility Contact Person: Owner Contact Phone No.: (209) 939-0961 <br />Make/Model of Monitoring System: Veederoot TLS350 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br />Date of Testing/Servicing: 3/5/2014 <br />Tank ID: #1 -Regular <br />Tank ID: #2 -Premium <br />® In -Tank Gauging Probe. <br />Model: 847390-109 <br />® In -Tank Gauging Probe. <br />Model: 847390-109 <br />® Annular Space or Vault Sensor. <br />Model: 794390-302 <br />® Annular Space or Vault Sensor. <br />Model: 794390-302 w Split tank <br />® Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />® Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />® Fill Sump Sensor(s). <br />Model: 794380-208 <br />® Fill Sump Sensor(s). <br />Model: 794380-208 <br />® Mechanical Line Leak Detector. <br />Model: Veederoot FX1 V <br />® Mechanical Line Leak Detector. <br />Model: VMI LD2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: ATG <br />® Tank Overfill / High -Level Sensor. <br />Model: ATG <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: #3 -Diesel <br />Tank ID: <br />Z In -Tank Gauging Probe. <br />Model: 847390-109 <br />❑ In -Tank Gauging Probe. <br />Model: <br />Z Annular Space or Vault Sensor. <br />Model: Split tank w/Prem <br />❑ Annular Space or Vault Sensor. <br />Model: <br />Z Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />Z Fill Sump Sensor(s). <br />Model: 794380-208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />Z Mechanical Line Leak Detector. <br />Model: Veederoot FX1 DV <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />Z Tank Overfill / High -Level Sensor. <br />Model: ATG <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />Z Dispenser Containment Sensor(s). <br />Model: 794380-208 <br />Z Dispenser Containment Sensor(s). <br />Model: 794380-208 <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />Z Dispenser Containment Sensor(s). <br />Model: 794380-208 <br />Z Dispenser Containment Sensor(s). <br />Model: 794380-208 <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 9-10 <br />Dispenser ID: 11-12 <br />Z Dispenser Containment Sensor(s). <br />Model: 794380-208 <br />Z Dispenser Containment Sensor(s). <br />Model: 794380-208 <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): ❑ System set-up ® Alarm history report <br />Technician Name (print): Jeff Conger Signature: <br />Certification No.: A22219 License. No.: ICC# 1801782 UT CSLB# 894932 <br />Testing Company Name: Pinnacle Fuel Compliance Services, Inc. Phone No.: (408) 206-9840 <br />Testing Company Address: P.O. Box 32849 San Jose, CA 95152-2849 Date of Testing/Servicing: 3/5/2014 <br />Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.