Laserfiche WebLink
Ah <br />r1 <br />MW <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sogov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />SHELL 1-5 <br />717 W EIGHTH ST STOCKTON <br />March 05 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR- Notice to Comply) <br />Item # <br />Remarks <br />126 <br />HSC 25404(e)(4) Failed to report program data electronically. <br />A complete submission to the California Electronic Reporting System (CERS) for the underground storage tank (UST) <br />program has not been made. Beginning January 1, 2014, all businesses are required to submit all new (or any <br />changes to existing) UST information, including: UST Monitoring Site Plan, UST Certification of Financial <br />Responsibility, UST Response Plan, UST Owner/Operator Written Agreement (if applicable), UST Letter from Chief <br />Financial Officer, and Owner Statement of Designated UST Operator Compliance online to the CERS at <br />http://cers.calepa.ca.gov. Be sure to include any other relevant activities and required fields. Items must now be <br />uploaded, "stored at site" is no longer a valid option for UST documents. Update and resubmit current/accurate <br />documents in CERS. Please review tank information and monitoring information for accuracy before resubmittal. <br />Update and resubmit the information through CERS immediately. Within 30 days, provide this office with written <br />documentation describing how this violation was corrected. If assistance is needed please contact Michelle Henry <br />and set up an appointment. <br />This is a minor violation. <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the 6/2104 and May/April <br />2014 designated operator monthly inspection report and failed to check that they were responded to appropriately. <br />The missing alarms include: L-8 diesel fill sump, fuel alarms on May 30 2014 and April 4, 2014. The april 4, 2014 <br />alarm did not show up on the alarm history printed on April 15, 2014 but did show up on the May 30, 2014 alarm <br />history. During the monthly inspection, the designated operator shall review the alarm history for the previous month, <br />check that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. Within 30 days submit <br />in writing to this office a statement addressing how this will be prevented in the future. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by April 5, 2015 . <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />Note: Inspector verified installation of sensors in the STP sumps. The sleeve was placed all the way against the <br />sump wall with the sensor sitting vertically, not tilted. In the sumps there is a small lip 1/2-1 inch that sticks out, <br />thus making the sensor sit out from the wall the same distance. In order to the sit directly under the lip the sensors <br />Received b <br />Inspector: <br />Phone: <br />Date: <br />(initia <br />MICHELLE HENRY, Senior REHS 1,1, <br />1 (209) 468-3454 <br />03/05/2015 <br />Page 4 of �-- <br />