2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2007-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
438
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:7 <br />4. TANK ANNULAR TESTING <br />Page 1 of —8- <br />Test Method Developed By: ❑ Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ®Vacuum ❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: vac gauge,stop watch <br />Equipment Resolution: -1.0 <br />Tank #Unleaded <br />Tank #Premium <br />Tank #Diesel Tank # <br />Is Tank Exempt From Testing?' <br />® Yes ❑ No <br />® Yes ❑ No <br />® Yes ❑ No ❑ Yes ❑ No <br />Tank Capacity: <br />Tank Material: <br />Tank Manufacturer: <br />Product Stored: <br />gasoline <br />gasoline <br />diesel <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (RI): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF-Ri): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />❑ Pass ;; ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail ❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />❑Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />El Yes ❑ No ❑NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testi n ? <br />RNA ❑ No❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes❑ No ❑ NA El Yes [:1 No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Note Premium/Diesel and Unleaded tanks are double wall tank wet annulars hydrostatic system. <br />PAGE -2 of 8 <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. <br />