Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2015
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2007-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
438
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of _8_ <br />10. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />Test Method Developed By: Sump Manufacturer X Industry Standard Professional Engineer <br />Other (Specify) <br />Test Method Used: Pressure Vacuum XHydrostatic <br />Other (Specify) <br />Test Equipment Used: Caldwell Level Indicator <br />Fill Sump #Unl Fill Sump #Prem <br />Equipment Resolution: .002 <br />Fill Sump #Diesel <br />Fill Sump # <br />Sump Diameter: <br />42 42 <br />42 <br />Sump Depth: <br />59 58 <br />59 <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />0 0 <br />0 <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />32 30 <br />30 <br />Condition of sump prior to <br />testing: <br />Clean Clean <br />Clean <br />Portion of Sump Tested <br />20 20 <br />20 <br />Sump Material: <br />Fiberglass Fiberglass <br />Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />15mins 15mins <br />15mins <br />Test Start Time: <br />30mins 30mins <br />30mins <br />Initial Reading (Ri): <br />first circle first circle <br />first circle <br />Test End Time: <br />Omins Omins <br />Omins <br />Final Reading (RF): <br />no change no change <br />no change <br />Test Duration: <br />30mins 30mins <br />30mins <br />Change in Reading (RF -RI): <br />0 0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30mins .005/30mins <br />.005/30mins <br />Test Result: <br />X Pass Fail XPass Fail <br />XPass Fail <br />Pass Fail <br />Is there a sensor in the sump? <br />XYes No XYes No <br />XYes No <br />Yes No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />XYes No NA XYes No NA <br />XYes No NA <br />Yes No NA <br />Was sensor removed for testing? <br />XYes No NA XYes No NA <br />XYes No NA <br />Yes No NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />Yes No XNA Yes No XNA <br />Yes No XNA <br />Yes No NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />All sensors are tested during annual monitoring certification. <br />Pate 8 of 8 <br />