Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Shell <br />Site Address: 717 W.Eighth Street <br />Facility Contact Person: Joe Dan Tran <br />Make/Model of Monitoring System: Veeder Root TLS350 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspect <br />Tank ID: Super <br />Dispenser ID: 7-8 <br />Z In -Tank Gauging Probe. <br />Model: 847390-109 <br />Z Annular Space or Vault Sensor. <br />Model: 794390-303 <br />Z Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />Z Fill Sump Sensor(s). <br />Model: 794380-208 <br />Z Mechanical Line Leak Detector. <br />Model: VMI Id2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />Z Tank Overfill / High -Level Sensor. <br />Model: Horn / Light <br />❑ Other (specify equipment type and <br />model in Section E on Page 2). <br />Tank ID: Diesel <br />Dispenser ID: 7-8 <br />Z In -Tank Gauging Probe. <br />Model: 847390-109 <br />Z Annular Space or Vault Sensor. <br />Model: 794390-303 <br />Z Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />Z Fill Sump Sensor(s). <br />Model: 794380-208 <br />Z Mechanical Line Leak Detector. <br />Model: Redjacket FX1 <br />❑ Electronic Line Leak Detector. <br />Model: <br />Z Tank Overfill / High -Level Sensor. <br />Model: Horn / Light <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Z Dispenser Containment Sensor(s). Model: 794380-208 <br />Z Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Bldg. No.: <br />City: Stockton Zip: 95206 <br />_ Contact Phone No.: (209) 939-0961 <br />Date of Testing/Servicing: 3/4/2013 <br />Tank m: Regular <br />Dispenser ID: 7-8 <br />Z In -Tank Gauging Probe. <br />Model: 847390-109 <br />Z Annular Space or Vault Sensor. <br />Model: 794390-303 <br />Z Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />Z Fill Sump Sensor(s). <br />Model: 794380-208 <br />Z Mechanical Line Leak Detector. <br />Model: RedjaCket FX1 <br />❑ Electronic Line Leak Detector. <br />Model: <br />Z Tank Overfill / High -Level Sensor. <br />Model: Horn / Light <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: Vent Transition <br />Dispenser ID: 7-8 <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />Z Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 3-4 <br />Z Dispenser Containment Sensor(s). <br />Model: 794380-208 <br />Z Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />Z Dispenser Containment Sensor(s). Model: 794380-208 <br />Z Dispenser Containment Sensor(s). Model: 794380-208 <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9-10 <br />Dispenser ID: 11-12 <br />Z Dispenser Containment Sensor(s). Model: 794380-208 <br />Z Dispenser Containment Sensor(s). Model: 794380-208 <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Hoat(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): ❑ System set-up ® Alarm history report <br />Technician Name (print): Aneil Chand <br />Certification No.: A21873 <br />Signature:���'�'--f <br />License. No.: ICC 5119959 <br />Testing Company Name: Pinnacle Fuel Compliance Services, Inc. Phone No.: (408) 206-9840 <br />Testing Company Address: P.O. Box 32849 San Jose, CA 95152-2849 Date of Testing/Servicing: 3/4/2013 <br />Page 1 of 3 <br />