Laserfiche WebLink
S A N ,J O A Q U I N Environmental Health Department <br /> - --COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PARADISE POINT ENGINE&BOAT REPAIR 8090 RIO BLANCO RD, STOCKTON October 25, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 505 CCR 66262.34(f)Failed to completely label stationary hazardous waste tanks. <br /> OBSERVATION: The hazardous waste tank storing used oil had a hazardous waste label that was missing the <br /> accumulation start date and the words"Hazardous Waste." <br /> REGULATION GUIDANCE: All hazardous waste tanks shall be marked with the words"Hazardous Waste"and the <br /> accumulation start date. <br /> CORRECTIVE ACTION: The violation was corrected during the inspection by Garland Powell,Shop Foreman, <br /> adding a hazardous waste label to the tank. No further action is required to correct this violation. <br /> This is a repeat violation, Class Il. <br /> 605 CCR 66262.34(f)Failed to completely label containers or portable tanks of hazardous waste. <br /> OBSERVATION: Hazardous waste containers were observed on-site with incomplete labeling. In the hazardous <br /> waste storage area: <br /> -One black 55 gallon steel drum containing oily absorbent(1/8 full)had a hazardous waste label that was missing <br /> the accumulation start date and the hazardous property. <br /> -One black 55 gallon steel drum containing waste gasoline had a hazardous waste label that was missing the <br /> accumulation start date. <br /> -One black 55 gallon steel drum containing waste gasoline had a hazardous waste label that was missing the <br /> accumulation start date,the name and address of the generator,the contents, and the words"Hazardous Waste." <br /> REGULATION GUIDANCE: All hazardous waste containers shall be marked with the following information: the <br /> words"Hazardous Waste", name and address of generator,hazardous properties, physical state, composition <br /> (contents),accumulation start date <br /> CORRECTIVE ACTION: The violation was corrected during the inspection by Garland Powell,Shop Foreman, <br /> correcting the labels. No further action is required to correct this violation. <br /> This is a repeat violation,Class II. <br /> FA0010125 PR0514182 SCO01 10/25/2019 <br /> EHD 22-01 Rev.9/20/2019 Page 4 of 6 Small Quantity Hazardous waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />