• Validation issues with report number 60734: <br /> Values reported for p,m-xylene that are below the MRL should be considered estimates. Values <br /> for p,m-xylene are reported to the lower CRDL of 0.50µg/L. <br /> Matrix spike/ matrix spike duplicate results associated with sample MW-30 for the analytes <br /> benzene and MtBE were affected by the analyte concentrations already present in the <br /> un-spiked sample. This flag was due to percent recoveries outside of QC limits. Relative <br /> percent difference (RPD) values were in QC range in the matrix spike (MS) and matrix spike <br /> duplicate (MSD) indicating a degree of precision. Both percent recovery and RPD values for <br /> benzene and MtBE were in range in the laboratory control spike (LCS) and laboratory control <br /> spike duplicate (LCSD) indicating both accuracy and precision,; thus, reported values are <br /> considered valid. <br /> The percent recovery for beryllium and chromim were outside of QC limits in the LCSD <br /> indicating a lack of accuracy in reporting. Both RPD values in the LCS/LCSD and MS/MSD for <br /> the two analytes were within QC ranges indicating precision in reporting. In addition, percent <br /> recovery for the two analytes was in range in the MS/MSD also indicating a degree of accuracy <br /> in reporting; thus, reported values are considered valid. <br /> Validation issues with report number 60756: <br /> Values reported for p,m-xylene that are below the MRL should be considered estimates. Values <br /> • for p,m-xylene are reported to the lower CRDL of 0.50 µg/L. <br /> Matrix spike/ matrix spike duplicate results associated with samples MW-9, MW-18, MW-21 and <br /> MW-22 for the analytes benzene and MtBE were affected by the analyte concentrations already <br /> present in the un-spiked sample and were out of QC limits for percent recovery. RPD values <br /> were in range indicating precision. Both RPD and percent recovery were in range in the <br /> LCS/LCSD indicating both accuracy and precision; thus, reported values are considered valid. <br /> Percent recovery for mercury in the MS/MSD was out of QC range indicating a lack of accuracy <br /> in reporting. RPD values were in range, indicating a degree of precision. In addition, both <br /> percent recovery and RPD values were in range for mercury in the LCS/LCSD; thus, reported <br /> values for mercury are considered valid. <br /> Percent recovery for cadmium was out QC limits in the LCSD. RpD values were in range in the <br /> LCS/LCSD indicating a degree of precision. Additionally, both percent recovery and RPD <br /> ranges for cadmium were within QC limits in the MS/MSD; thus, reported values for cadmium <br /> are considered valid. <br /> Hydrocarbons reported as TPHo were lower boiling point than typical motor oil for sample <br /> MW-9. <br /> The method reporting limit for TPHd was increased due to interference from gasoline range <br /> hydrocarbons for sample MW-18. <br /> • <br /> 1008OSSRORSRQMR.Final.doc 15 April 30,2008 <br /> 77TW.26397.42.1307 <br />