Laserfiche WebLink
S E C O R <br /> • SPH or sheen has historically been reported in well 2AMW-14 since May 2002 (Table 3, Figure <br /> 9). Historical thickness of SPH in that well has ranged from 0.21 feet reported during the initial <br /> monitoring event in May 2002 to a maximum thickness of 2.99 feet reported during the fourth <br /> quarter 2003. As discussed above, well 2AMW-14 was not assessed during the first through <br /> fourth quarters of 2004 due to its connection to a free product removal system. However, well <br /> 2AMW-14 has been accessible for the last 13 consecutive quarters. SPH or sheen has <br /> historically been reported in well MW-10 since February 2004 and has ranged in thickness from <br /> 0.01 to 3.09 feet (February 2007; Table 3). <br /> Historical measurable thickness of SPH in well MW-21, DPE wells DPE-1, DPE-2, DPE-3, <br /> DPE-4, DPE-6, DPE-7, DPE-8, and DPE-10 has ranged from 0.01 feet (DPE-12, February <br /> 2005) to a Site-wide maximum thickness of 11.72 feet(DPE-1, November 2003). <br /> A summary of first quarter 2008 SPH thickness and SPH sheen in comparison to the fourth <br /> quarter of 2007 is provided in the following table. <br /> SPH SPH <br /> Well Thickness Thickness Difference <br /> Identification 4Q07 (Feet) 1Q08 (Feet) Feet <br /> MW-10 Sheen Sheen 'NA <br /> 2AMW-13 ND Sheen "NA <br /> 2AMW-14 Sheen Sheen NA <br /> • MW-19 NA Sheen 'NA <br /> DPE-1 Sheen Sheen NA <br /> DPE-2 Sheen Sheen NA <br /> DPE-3 ND Sheen NA <br /> DPE-4 0.08 0.30 +0.22 <br /> DPE-5 Sheen Sheen NA <br /> DPE-6 Sheen 0.30 NA <br /> DPE-7 Sheen Sheen NA <br /> DPE-8 0.01 0.02 +0.01 <br /> DPE-9 Sheen Sheen NA <br /> DPE-10 Sheen Sheen NA <br /> DPE-11 Sheen Sheen NA <br /> DPE-12 ND 0.05 NA <br /> DPE-13 NA Sheen NA <br /> Definitions: <br /> NA = Not Applicable/Not Available <br /> ND = SPH or sheen not observed <br /> = SPH Removal occurred prior to groundwater sampling. <br /> SPH removal activities are scheduled to be conducted quarterly (at a minimum) for on and off <br /> • Site wells which repeatedly contain measurable thickness of SPH. It should be noted that these <br /> 1Q08QSSRQRSRQMR.F1na1.doc 21 April 30,2008 <br /> 77TW.26397.42.1307 <br />