Stantec <br /> L & M OPERABLE UNIT-THIRD QUARTER 2010 SITE STATUS, REMEDIAL SUMMARY, <br /> AND GROUNDWATER MONITORING REPORT <br /> Status of Remediation Activities <br /> October 27, 2010 <br /> 3.2 APARTMENT SVE SYSTEM <br /> The Apartment SVE (ASVE) system has operated near continuously since May 31, 2007 <br /> following retrofit construction that began on December 12, 2006. The ASVE system is <br /> ' comprised of horizontal wells (ASVE-1 through ASVE-6), a 100-gallon liquid/vapor separator, <br /> and a Solleco 250 cubic feet per minute (cfm) vapor extraction system with a Roots URAI 56 <br /> 10-hp positive displacement blower. Vapor from both the ASVE and the SVE (discussed in <br /> ' section 3.3) system is abated with a 750 scfm thermal oxidizer. <br /> Since May 31, 2007 the 750 scfm SVE and ASVE vapor abatement system has been operated <br /> under SJVAPCD ATC number N-4878-2-0. <br /> The ASVE system has removed approximately 2,076 pounds (340 gallons) of TPHg, and <br /> ' 0.13 pound (0.02 gallon) of benzene from soil vapor beneath the Delta View Apartments to date. <br /> No measurable MtBE has been removed to date. During 3Q10 (July 12, 2010 to September 15, <br /> 2010), no measurable amount of TPHg, benzene, or MtBE was removed. The ASVE system <br /> ' was shutdown from August 28, 2010 to September 15, 2010 for due to the automatic shutdown <br /> of the DPE system and subsequent repairs and modifications to the system. Historical ASVE <br /> system operations and analytical data are presented in Tables 18 through 20. <br /> ' 3.3 SVE SYSTEM <br /> The SVE system has run near continuously since May 31, 2007 following retrofit construction <br /> that began on December 12, 2006. The SVE system is comprised of horizontal vapor wells: <br /> SVE-1 through SVE-11, a 100-gallon liquid/vapor separator, and a Solleco 500 cfm vapor <br /> ' extraction system with a Roots URAI 59 20-hp positive displacement blower. Vapor from both <br /> the ASVE and the SVE system is abated with a 750 scfm thermal oxidizer. <br /> ' Since May 31, 2007 the 750 scfm SVE and ASVE vapor abatement system has been operated <br /> under SJVAPCD ATC number N-4878-2-0. <br /> ' The SVE system has removed approximately 2,243 pounds (368 gallons) of TPHg and <br /> 0.14 pound (0.02 gallon) of benzene from soil vapor beneath the L&M OU to date. No <br /> measurable amount of MtBE has been removed to date. During 3Q10 (July 12, 2010 to <br /> ' September 15, 2010), the SVE system removed approximately 64.8 pounds (10.6 gallons) of <br /> TPHg soil vapor. No measurable amount of TPHg, benzene, or MtBE was removed. The SVE <br /> system was shutdown from August 28, 2010 to September 15, 2010 for due to the automatic <br /> ' shutdown of the DPE system and subsequent repairs and modifications to the system. <br /> Historical SVE system operations and analytical data are presented in Tables 21 through 24. <br /> ' IMdewterl Stacton(Paae12A.0415)\Reports\oMR@010\0n10\3p100SSRQRSROMR Stmkton_FINALCoc 3.2 <br />