My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_COMPLIANCE INFO 2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2923
>
1600 - Food Program
>
PR0545349
>
COMPLIANCE INFO_COMPLIANCE INFO 2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2020 12:00:26 PM
Creation date
6/25/2020 9:12:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
COMPLIANCE INFO 2020
RECORD_ID
PR0545349
PE
3611
FACILITY_ID
FA0025761
FACILITY_NAME
REVEL LODI
STREET_NUMBER
2923
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2923 REYNOLDS RANCH PKWY
P_LOCATION
02
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S ` ` , J O A Q U I N Environmental Health Department <br /> C0U "ATY <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: REVEL LODI, 2923 REYNOLDS RANCH PKWY, LODI 95240 <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The East side underwater light is not functioning. Repair or replace within one month. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #37 Electrical Hazards <br /> OBSERVATIONS:The ground-fault circuit interrupter(GFCI)cannot be tested due to the unknown location of GFCI. <br /> Located the GFCI and test it within one week. <br /> CALCODE DESCRIPTION:Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br /> California Electrical Code. (CEC 680.4)Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br /> fault circuit interrupter. (CBC 31608) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 95 gpm Chlorine: 168 ppm Temp: ° F <br /> Cyanuric acid: 0 ppm pH: >8 Combined chlorine: 0 ppm <br /> NOTES <br /> Routine inspection conducted this date. The followings were noted: <br /> Influent: 20 psi; Effluent: 15 psi. <br /> Self-closing and self-latching gate was tested and functional. <br /> The RP device for auto fill shall be tested annually. <br /> Inspection report was discussed with Percy Bergquist, Maintenance Director. <br /> Inspection report will be e-mailed to the facility. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: <br /> EH Specialist: STEVEN SHIH Phone: (209)468-9850 <br /> FA0025761 PR0545349 SCO01 06/19/2020 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.