Laserfiche WebLink
The following is an itemized list of hazardous waste violations that have not been <br /> addressed for CHASE CHEVROLET as of September 25, 2019. <br /> Open violations from September 13, 2019 inspection <br /> )IM This violation was corrected ❑This violation will be corrected by(date): <br /> -)F Supporting documents included ++ <br /> Describe actions taken or will be taken to correct violation: A 0e I'd 4h-t-A C6,ew ul e rS <br /> h'iIsSIA61 kA e.rAbvl� •J�,SrC IQ�c1S . Sed �-�rt�/' 06+05 . <br /> Violation#503-Hazardous waste tank assessment Is incomplete. <br /> OBSERVATION:The hazardous waste tank assessment for the 120 gallon used antifreeze stationary tank and the <br /> 294 gallon used oil stationary tank is incomplete.The report prepared and signed by the professional engineer on <br /> 8-24-15,certifies each tank as complying with subsection CCR 66265.192(k).The tank assessment did not contain <br /> the full required Title 22 Section CCR 66265.192. <br /> REGULATION GUIDANCE:The hazardous waste tank assessment shall include all of the following information: <br /> 1,tank configuration (i.e., horizontal,vertical), material of construction, and gross capacity(in gallons); <br /> 2.design standard(s), if available,according to which the tank and ancillary equipment were or will be <br /> constructed and all of the following information: <br /> A. material of construction; <br /> B. material thickness and the method used to determine the thickness; <br /> C. description of tank system piping (material,diameter); <br /> 0.description of any internal and extemal pumps; and <br /> E. sketch or drawing of tank including dimensions. <br /> 3.documented age of the tank system(if tank was previously used),if available, (otherwise,an estimate of the <br /> age); <br /> 4.description and evaluation of any leak detection equipment; <br /> 5.description and evaluation of any corrosion protection equipment, devices,or material; <br /> 6.description and evaluation of any spill prevention or overfill equipment; <br /> 7.description and evaluation of secondary containment for the tank system including applicable secondary <br /> containment for ancillary equipment as required in subsection 66265.193(f); <br /> B. hazardous characteristics of the wastes that have been or will be handled. <br /> CORRECTIVE ACTION: Immediately amend the tank system assessment to include all required information as <br /> required in Title 22 Section CCR 66265.192 and submit a copy of the amendments to the EHD. <br /> 1, This violation was corrected ❑This violation will be corrected by(date): <br /> JS Supporting documents included I1 <br /> Describe actions taken or will be taken to correct violation: (or%JAG�-� � r� 14 r��torike r ^4" <br /> re Ve t Itkl r �a,n .n ri�M a.el, 44A F esik-,'A- <br /> A,,A <br /> -A,,A Se-InV nn ; .,eS L S G(tfFlar�-� jpbkx 46 Cfh-A10'h M Ura <br /> A nrbJI'Al C, SrI [sua <br /> Page 5 of 7 <br />