My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOLMAN
>
6441
>
2200 - Hazardous Waste Program
>
PR0514322
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/25/2020 4:45:20 PM
Creation date
6/25/2020 10:49:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0514322
PE
2229
FACILITY_ID
FA0010424
FACILITY_NAME
CHASE CHEVROLET
STREET_NUMBER
6441
STREET_NAME
HOLMAN
STREET_TYPE
RD
City
STOCKTON
Zip
95212
CURRENT_STATUS
01
SITE_LOCATION
6441 HOLMAN RD
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Spill Prevention Compliance Corporation <br /> P.O. Box 1289........Waterford, CA 95386 Telephone: (209)969-0851 <br /> Email: agmM@hotmaii.com <br /> Website: www.spcpian.com <br /> Certified Assessment Form (PE) for AST Systems <br /> Assessor: Spill Prevention Compliance Corporation Onsite Assessor: Todd McWhorter <br /> P.O.Box 1289 Telephone: (209)969-0851 <br /> Waterford,CA 95386 email: spccory(ftotmail.com <br /> Client: Chase Chevrolet Contact : Alex Robinson,Service Manager <br /> Address: 6441 Holman Rd. Phone No.: 209475-6640 <br /> City/State/Zip; Stockton, CA 95212 Date of Test: 10-9-19 <br /> Assessment Data-Waste Oil AST-b <br /> 1. AST Configuration &age of AST Horizontal AST Double wall steeVapprox 14 yrs old{0812005) <br /> Ia. Useful Life Remaining of AST AST has avoroximately 30 years of remaining life (Subsection kl-k10) <br /> 2. AST Primary vessel construction(describe) 1500 gals/Waste Oil/UL# P-77880/UL142-Container/Made to <br /> UL 142 construction standard-at least.167 in.steel thickness pjr UL Std for Safety for Steel Aboveground <br /> Tanks for Flammable and Combustible Liquids,suitable for containing waste oil. <br /> 3. AST piping(describe) 1 in. hydraulic hose to 1 in.copper pipe from four(4)Graco Husky 1040 pneumatic <br /> pumps to 1 in. hydraulic hose to 2 in openine wlfittins,from pump for supply to top of AST.There is an <br /> inline check valve between sugPly hoses & Pump. Piping is adequately secured supeorted& protected <br /> a ninst physical dama a and excessive stress due to settlement vibration expansion or contraction & was <br /> tested,found to be in good condition& not leaking. <br /> 4. Internal/External pump description external steel pillar mounted four 4 Graco Husky 1040 pneumatic <br /> pumps w/2 solenoid 12volt-10-200psi-w/continuous electronic monitoring& pneumatic auto shut down- <br /> Pumping is Initially from op2rations containment boxes to numv via hydraulic hoses and then to the AST. <br /> External pump,which lRamps from traveling containment boxes which receives roduct from vehicles above <br /> and then is pumpgd into the AST. The pumps have an inline check valve to prevent siphoning thru sunply <br /> hoses. Ancillary equipment is secured to wall &supported and Protected a ninst iphysical dama a and <br /> excessive stress due to settlement,vibration expansion or contraction see is <br /> 5. AST drawing(provided/drawn: source) (see attached) <br /> 6. Design Standard(ASME, UL,etc.) UL 142-Double Wall Steel/Mfr: Containment Solutions <br /> 7. AST foundation(describe) concrete sub-floor,Base of AST under UL 142 adequate to withstand the load <br /> of a full tank-Tank is anchored to concrete basement floor. <br /> 8. AST anchoring(seismic zone/floatation risk)AST is anchored,with steel flange anchor feet, which are <br /> welded to outer shell of tank, &3/4 in. anchor bolts into the concrete floor,thru the openings provided in the <br /> tanks anchor flanges. Stockton is a(eroundshaking)seismic region, These anchors are intended,to secure the <br /> tank durin a seismic event.There are two scenarios which would create loads upon them. The first scenario <br /> is an empty tank. With an empq tank, the exaansion anchors resist the overturning moment through their <br /> tensile(Pull-out cuipacity. Since the anchors are installed at the Mrimeter of the tank the distance between <br /> anchors in either directionprovides a sufficient lever arm for the concrete anchors to not exceed their <br /> allowablepull-out capacity. The second load case is with a partially. full or full tank. In this scenario because <br /> the liquid fills the bottom of the tank and increases its weight,the ooverning load case becomes the shear <br /> capacity of the concrete expansion anchors In the shear loading,all anchors resist the loads and their <br /> C) allowable capacity is not exceeded. This load case Is conservative in its analysis since it neglects the friction <br /> force created by the weight of the aartially full or full tank. This tank's rear is against the concrete suvvort <br /> structure at the wall,which further acts as a barrier to movement in the event of an earthquake.AST is <br />
The URL can be used to link to this page
Your browser does not support the video tag.