My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2624
>
1600 - Food Program
>
PR0545900
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2020 9:04:59 AM
Creation date
6/25/2020 1:33:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0545900
PE
1613
FACILITY_ID
FA0025959
FACILITY_NAME
SEE'S CANDIES
STREET_NUMBER
2624
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
CURRENT_STATUS
01
SITE_LOCATION
2624 W KETTLEMAN LN #140
P_LOCATION
02
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OCCUPANT LOAD CALC. Revisions <br /> 01-16-2020 <br /> FRONT EXIT <br /> SALES AREA: 613 SQ. FT. 02-04-2020 <br /> OCCUPANT LOAD FACTOR: 60 <br /> 613/60= 10 10 OCCUPANTS Q <br /> 1 EXIT REQUIRED <br /> w <br /> NON-SALES AREA: 487 SQ. FT. _ <br /> OCCUPANT LOAD FACTOR: 300 w <br /> 487 /300=2 2 OCCUPANTS <br /> 1 EXIT REQUIRED 0 <br /> 0 <br /> z <br /> OFFICE: 0 SQ.FT. w <br /> OCCUPANT LOAD FACTOR: 200 ILI <br /> 0/200=0 0 OCCUPANTS Z <br /> 0 EXIT REQUIRED o <br /> z <br /> a <br /> m <br /> TOTAL OCCUPANT LOAD: 12 OCCUPANTS <br /> (� mr O E <br /> O m �n <br /> m ,--I rn p O <br /> Z <br /> Q E Ln <br /> O J i <br /> M O 00 = O <br /> a a. `.� Ln i L <br /> GBG 2016 TABLE 1011.2 ? LU -19 <br /> U oo <br /> EXIT ACCESS TRAVEL DISTANGE: D " 0 <br /> 250 FT TOTAL DISTANCE <br /> ALLOWED WITH 5PRINKER • f-- w IA 1A <br /> IA 1A <br /> SYSTEM. • o LU 00iA s <br /> • <br /> s <br /> M OCCUPANCY : 0 U C <br /> ACTUAL DISTANCE= 72-0" • <br /> • o Q _ <br /> I I • <br /> Q <br /> M OCCUPANCY z0 <br /> WORK AREA=504 5F ,lee <br /> 00 0 <br /> 487 5F/300 = 2 OCCUPANTS <br /> 1 EXIT REQUIRED z <br /> r7 <br /> V <br /> • w aoeZ <br /> • � m <br /> • Q <br /> 00- 9 <br /> Y r <br /> 0 W U <br /> • 2 a _ <br /> O] J <br /> � V <br /> • U fn Q <br /> U � <br /> • U <br /> 2 :D <br /> • U <br /> • V <br /> O <br /> z � <br /> TACTILE EXIT 51GN 'B', • Z <br /> SEE DETAIL TH15 SHEET 0 <br /> ILLUMINATED • <br /> EXIT 516N • DAR <br /> Z �V��F S.BHghO�l� <br /> TACTILE EXIT SIGNS <br /> Q *� No.C-28803 <br /> • \ EACH GRADE LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A TACTILE EXIT WITH THE 9TF -30�OQ� <br /> • CV WORD"EXIT." PER CBC 1003.2.8.6 OF CAI k <br /> • EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF A <br /> • STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE FOLLOWING <br /> • WORDS AS APPROPRIATE: R <br /> ° w <br /> • N 1. "EXIT STAIRS DOWN" <br /> • 2. "EXIT RAMP DOWN" w <br /> • 3. "EXIT STAIR UP" o <br /> • 4. "EXIT RAMP UP" w <br /> • <br /> • EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF AN <br /> • EXIT ENCLOSURE OR AN EXIT PASSAGEWAY SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN z <br /> NOT A PART • NOT A PART WITH THE WORDS"EXIT ROUTE." PER CBC 1003.2.8.6 <br /> 0 <br /> j W LU C51 <br /> EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY <br /> ACCE551BLE COUNTER • ® THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN,SHALL BY IDENTIFIED BY A TACTILE EXIT SIGN <br /> HEIGHT 34" A.F.F. • "I WITH THE WORDS"EXIT ROUTE." Z W <br /> � EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED BY A SIGN WITH THE <br /> a � <br /> WORDS"TO EXIT." o <br /> • <br /> N <br /> • z Z � <br /> • 3 > o JLO <br /> N <br /> • o Z � <br /> M OCCUPAOCCUPANT <br /> LO • EXIT w CY <br /> CA a a <br /> OCCUPANT LOAD FACTOR = 1/60 SF • ae ' C <br /> BALES AREA= 690 5F _ CW V <br /> 613 5F/60 = 10 OCCUPANTS • w <br /> 1 EXIT REQUIRED, 1 PROVIDED co _ Q <br /> O <br /> • w W J <br /> • 3 w 04 <br /> N <br /> GBG 2016 TABLE 1006.3.2 BASELINE EXIT <br /> COMMON PATH OF EGRESS TRAVEL • OF TOP ^ <br /> DISTANCE: • LINE ROUTE <br /> 75 FT TOTAL DISTANCE ^ M z <br /> M OCCUPANCY • r <br /> ACTUAL DISTANCE = 65-0" • <br /> • LL <br /> ¢ Z <br /> • O a <br /> • `0 5E 'y <br /> ILL <br /> w <br /> • °O ¢ ~o <br /> � o <br /> M OCCUPANCY `•• <br /> a <br /> TOTAL CUMULATIVE OCCUPANTS: • TACTILE EXIT 51GN 'A', } Sheet Content <br /> 2+ 10 = 12 • SEE DETAIL TH15 SHEET NOTES O <br /> 1 EXIT REQUIRED, 1 PROVIDED • ILLUMINATED 1. FOR MOUNTING LOCATIONS, REFER TO SIGNAGE MOUNTING DETAIL 9/-, MEANS OF <br /> • EXIT 516N 2. SIGN TO BE 1/8" THICK STAINLESS STEEL. 0 <br /> iE EGGRESS PLAN <br /> iE <br /> • 3. PROVIDE 1/32" RAISED TEXT BETWEEN 5/8" - 2" TALL & OF A CONTRASTING COLOR. U AND DETAILS <br /> %• 4. PROVIDE GRADE 2 BRAILLE BELOW TEXT. <br /> w <br /> CONST DOCS <br /> SYMBOL LEGEND <br /> Document Status <br /> (� o plan chk after <br /> o bidding permit <br /> O MATERIAL FIN15H DE516NATION, BEE SHEET A2.1 0 <br /> Date: 02/04/2020 <br /> 101 DOOR DE51ONATION -SEE DOOR SGHEDULE ON SHEET A5.1 <br /> Drawn by: EG <br /> OA2 STOREFRONT DESIGNATION -SEE SCHEDULE ON SHEET A5.1 0 <br /> TRUEChecked by: JB <br /> m <br /> KEYNOTE DE51ONATION Project: 19-503.36 <br /> 1 WALL DESIGNATION -SEE LEGEND ON SHEET A1.1 Sheet Number <br /> Room name <br /> 101 ROOM NAME DESIGNATION <br /> MEANS OF EGRESS <br /> 1 <br /> A1@3 <br /> 2019 SCHUSS CLARK BRANDON <br /> SCALE: 1/4" = V-0" <br /> ARCHITECTS, INCORPORATED <br /> PRINTED: 2/5/202011:31:11 AM <br />