Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
SA NUJ OAHU I N Environmental Health Department <br /> ■ COUNT Y-- <br /> c/ `p Greol:ness grows hey,. Timeln: 1-00pm <br /> Time Out: 2:00 om <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: IN SHAPE HEALTH CLUB-WEST LANE Date: 06/22/2020 <br /> Address: 1074 E BIANCHI RD, STOCKTON 95210 <br /> Owner/Operator: ROTHBARD, DR MORT Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:The following signs were missing. Provided within one week: <br /> • Keep closed signed is missing.A sign shall be posted on the exterior side of gates and doors leading into the pool <br /> enclosure area stating, "KEEP GATE CLOSED"or"KEEP DOOR CLOSED". <br /> • Diarrhea Sign:The pool operator shall post at the entrance area of a public pool, a sign in letters at least 1 inch (25 mm) <br /> high,that clearly states that persons with diarrhea and persons who have had diarrhea within the prior 14 days shall not <br /> enter the pool water. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Five underwater lights are not functioning. Repair/replace these underwater lights within one month. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #37 Electrical Hazards <br /> OBSERVATIONS:Pump is not bonded. Provide this pump with bonding wire to prevent the transmission of any harmful <br /> electrical voltage to pool equipment and people. Correct within one week. <br /> CALCODE DESCRIPTION:Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br /> California Electrical Code. (CEC 680.4)Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br /> fault circuit interrupter. (CBC 3160B) <br /> #38 Filter Cleaning and Maintenance <br /> OBSERVATIONS:The pressure differential between influent and effluent was at 12 psi for outside sand filters. <br /> Clean/replace the filters within one month. <br /> CALCODE DESCRIPTION:All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B)Pressure gauge <br /> located on the filter shall be marked with the clean startup reading. (CBC 3125B)Each filter vessel shall be provided with valves so that it <br /> can be isolated from the recirculation system for repairs and backwashing. (CBC 31288) <br /> FA0001120 PR0360182 SCO01 06/22/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />