FA0012466
FACILITY_NAME
PREMIER FINISHING
STREET_NUMBER
7910
Direction
S
STREET_NAME
LONGE
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
7910 S LONGE
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
588
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of hazardous waste violations that have not been <br /> addressed for PREMIER FINISHING as of June 27 , 2019 . <br /> Open violations from January 15 , 2019 inspection <br /> Violation #102 - Failed to determine if a waste is a hazardous waste. <br /> 1 ) Waste powder coating is dried in an oven on site and then disposed of via landfill . Immediately cease disposal <br /> and make a complete hazardous waste determination on the waste powder coating at the point of the waste <br /> generation ( before it gets placed in an oven ) . <br /> 2 ) Nine 5 gallon buckets containing an oily water liquid were observed near a compressor . <br /> 3 ) Three blue 55 gallon steel drums , one labeled " pressure washer gutter waste were observed in the external <br /> power washing containment area . <br /> 4 ) One open tray (4ft x 4ft) containing a pile of " burn -off" residue was underneath a cover in the external power <br /> washing area . <br /> 5 ) One metal garbage can (3/4 full ) containing an absorbent and a dark solid was located in the external power <br /> washing containment area . <br /> 6 ) Liquid from the external power washing area was observed going into the storm drain . There were also pools of <br /> the liquid in a secondary containment. <br /> 7) Two open 10-gallon buckets capture powder discharged from the air filtering system in the north building . <br /> 8) Paint booth filters from several locations around the facility are changed daily. <br /> 9) One red five gallon can partially full of solid paint waste was observed in the new maintenance area . <br /> 10) Sand blast media was covering the ground in a trailer. <br /> Any person who generates a waste shall determine if the waste is a hazardous waste . Immediately cease disposal <br /> and make a complete hazardous waste determination for the above listed wastes . Manage them according to Title <br /> 22 hazardous waste regulations . Submit a statement and supporting documentation explaining how each waste <br /> was managed . <br /> Violation #122 - Failed to provide information for > 100 kg/mo recyclable material to claim the exclusion or <br /> exemption . <br /> Acetone and Jem Strep 427 are being recycled and all required information to claim the exclusion or exemption has <br /> not been submitted . <br /> The following items were missing from both recyclable material reports : the beginning and end date of the reporting <br /> period , the signature of the certifier, the recyclable material number, the quantity during the two year reporting <br /> period , and the authorizing provision of HSC Section 25143 . 2 . <br /> To claim an exclusion or exemption from classifying this as a waste , the following information shall be submitted <br /> every two years : <br /> - name , site address , mailing address , and telephone number of the owner or operator of the facility that recycles <br /> the material ; <br /> - name and address of the generator of the recyclable material ; <br /> - documentation that the requirements of any exemptions or exclusions pursuant to HSC 25143 . 2 are met. <br /> Immediately provide all required information for every recyclable material that you wish to claim the exclusion or <br /> exemption and provide that information every two years . If the required information cannot be provided , the <br /> materials must immediately be handled as a hazardous waste . <br /> Violation #501 - Failed to completely label stationary hazardous waste tanks . <br /> The 234 gallon hazardous waste tank on the plating line in the north section of the facility was observed without a <br /> label . The tank is used to store hazardous waste before going through the pipe to the other side for treatment. All <br /> hazardous waste tanks shall be marked with the words " Hazardous Waste" and the accumulation start date . <br /> Immediately ensure that all hazardous waste tanks are marked with the required information . <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.