Laserfiche WebLink
FA0012466 PRO516115 SC001 01/15/2019 <br />EHD 22-02 Rev. 09/22/16 Page 4 of 12 Large Quantity Hazardous Waste Generator O1R <br />Sail Joaquin rourriy <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sogov.org/ehd <br />L..arge Quantity Hazardous Waste Generator Inspection Report <br />Facility <br />Name: <br />Facility Address: <br />Date: <br />PREMIER FINISHING <br />7910 S LONGE, STOCKTON <br />January 15, 2019 <br />Universal Waste <br />717 <br />CCR 66273.32(b) <br />UWH failed to obtain an ID number from DTSC prior to accumulating >5000kg of non-RCRA UW <br />a V ❑ R ❑ COS <br />718 <br />CCR 66273.32(d) <br />Failure of a UW handler to submit a complete annual report to DTSC <br />❑ V o R o COS <br />719 <br />CCR 66273.38 <br />Failure of UW handler to transfer UW to the appropriate destination facility <br />❑ V ❑ R ❑ COS <br />720 <br />CCR 66273.31(a) <br />UW handler caused improper disposal of UW <br />❑ V ❑ R ❑ COS <br />721 <br />CCR 66273.8(b) <br />Conditionally exempt small quantity UW generator caused improper disposal of UW <br />o V ❑ R o COS <br />Appliance Recycler <br />801 <br />HSC 25211.4 <br />Failure to obtain Certified Appliance Recycler certification (CAR) <br />❑ V ❑ R ❑ COS <br />802 <br />HSC 25211.2, 25211.3 <br />Failure of a CAR to provide docs that materials that require special handling have been removed <br />o V ❑ R ❑ COS <br />803 <br />HSC 25212 <br />Failure of a CAR to properly remove and dispose of all materials that require special handling <br />❑ V ❑ R ❑ COS <br />Other Violations <br />3010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V a R o COS <br />3020 <br />See below <br />Unlisted Training violation <br />a V o R a COS <br />3030 <br />See below <br />Unlisted Operations/Maintenance violation <br />o V a R ❑ COS <br />3040 <br />See below <br />Unlisted Releasell-eaks/Spills violation <br />o V o R ❑ COS <br />3050 <br />See below <br />Unlisted Abandonmentlillegal Disposal/Unauthorized Treatment violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />102 <br />CCR 66262.11 Failed to determine if a waste is a hazardous waste. <br />1) Waste powder coating is dried in an oven on site and then disposed of via landfill. Immediately cease disposal <br />r. <br />and make a complete hazardous waste determination on the waste powder coating at the point of the waste <br />generation (before it gets placed in an oven). <br />2) Nine 5 gallon buckets containing an oily water liquid were observed near a compressor <br />3) Three blue 55 gallon steel drums one labeled 'pressure washer gutter waste", were observed in the external <br />power washing containment area. <br />4) One open tray (4ft x 4ft) containing a pile of 'burn-ofr residue was underneath a cover in the external power <br />washing area. <br />5) One metal garbage-can (3/4 full) containing an absorbent and a dark solid was located in the external power <br />ashing containment area. <br />. 8) Liquid from the external power washing area was observed going into the storm drain There were also pools of <br />'tlzehlquid in a secondary containment. <br />7) Two open 10-gallon buckets capture powder discharged from the air filtering system in the north building <br />8) Paint booth filters from several locations around the facility are changed daily. <br />9) One red five gallon can partially full of solid paint waste was observed In the new maintenance area. <br />10) Sand blast media was covering the ground in a trailer. <br />Any person who generates a waste shall determine if the waste is a hazardous waste. Immediately cease disposal <br />and make a complete hazardous waste determination for the above listed wastes. Manage them according to Title <br />22 hazardous waste regulations. Submit a statement and supporting documentation explaining how each waste <br />was managed. <br />This is a repeat violation, Class ll. <br />FA0012466 PRO516115 SC001 01/15/2019 <br />EHD 22-02 Rev. 09/22/16 Page 4 of 12 Large Quantity Hazardous Waste Generator O1R <br />