Laserfiche WebLink
Site Inspection UFP-QAPP Addendum <br />Stockton AASF, Stockton, California <br />Example PFAS Daily Sampling Checklist <br />Team Members <br />Yes <br />No <br />Description <br />Has AECOM PFAS Sampling guidance been reviewed by all team members? <br />Comments' <br />Yes <br />No <br />Has AECOM field sampling staff received needed training certification? <br />Comments' <br />Yes <br />No <br />Was a briefing held for field sampling staff? <br />Comments: <br />Yes <br />No <br />Were additional PFAS sampling instructions given to field samoag st3V <br />Comments: <br />Yes <br />No <br />Have personal doftig and PPE requirements been followed by all field sampling <br />stag? <br />Comments: <br />Yes <br />Ho <br />Were lotions and sunscreen used far field sampling staff? <br />Comment: <br />Sample Collection <br />Yes <br />No <br />Has s P FAS -flee water source been idenlfied? <br />Comment <br />Source of PFAS-tree water <br />Yes <br />No <br />Have all samping items, parts and equipment been inspected to be free of PFAS? <br />Comment: <br />Yes <br />No <br />Has sampling locatlon sequence been oommunicated to avoid crna&-contaminations? <br />Comment. <br />Yes <br />No <br />Have driiIing fluids been evaluated and strewn to be free of PFAS? <br />Comment: <br />Yes <br />No <br />Use of PFAS-free decontamination solution? <br />Brand name of decontamination sokution- <br />Yes <br />No <br />Have all Bald logs, notebooks, pens, labels been inspected, and do they meet <br />AECOM PFAS sampling gudance requirements? <br />Comment <br />Yes <br />No <br />Have all sample shipping materials (ice_ ii*c bugs) been inspected, and do they <br />meet AECOM PFAS sampling guidance regv,remenla? <br />Comment: <br />Yes <br />No <br />Have all blanks arrived at the site and will they be coleched to verify <br />crass-contavninaborl? <br />Comment <br />Other Comments: <br />Personnel Qualifications <br />All personnel mobilized to the site will meet applicable Occupational Safety and Health <br />Administration (OSHA) training requirements including hazardous waste operations and <br />emergency response (HAZWOPER) training and medical surveillance requirements as specified <br />in the Accident Prevention Plan (APP) and Site Safety and Health Plan (SSHP). Personnel will be <br />required to complete the DoD's Operations Security Awareness for Military Members, DoD <br />Employees, and Contractors and Level 1 Antiterrorism Awareness Training. Additionally, all <br />AECOM employees that will be performing field work will take an internal PFAS sampling <br />guidance training. <br />Permits and Notifications <br />Utility clearance will be conducted by CAARNG with input from the AECOM field team or by a <br />private utility location company if CAARNG cannot provide clearance. A minimum of two weeks <br />to coordinate the clearance will be required. AECOM or its drilling subcontractor will contact <br />California 811, the local one -call utility location system. AECOM and the drilling subcontractor will <br />participate in a Stockton AASF orientation prior to initiating work, if required. The determination of <br />the orientation requirement will be made after final intrusive investigation locations are <br />determined. AECOM will also contact the ARNG Environmental Manager at least five business <br />days prior to the scheduled start of the field activities. A site walk will be scheduled with the <br />appropriate ARNG personnel to mark out locations of the subsurface utilities. As a precaution, the <br />first 5 feet of each boring will be pre -cleared using hand tools (e.g., post -hole diggers, augers, <br />AECOM QAPP Worksheet #17 <br />Page 3 of 10 <br />