My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2895
>
2200 - Hazardous Waste Program
>
PR0517823
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/29/2020 3:03:41 PM
Creation date
6/29/2020 2:55:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0517823
PE
2229
FACILITY_ID
FA0013604
FACILITY_NAME
TRACY TOYOTA
STREET_NUMBER
2895
Direction
N
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21229004
CURRENT_STATUS
01
SITE_LOCATION
2895 N NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN ,dDAQ U I N Environmental Health Department <br /> C01-1 N T <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY TOYOTA 2895 N NAGLEE RD, TRACY December 05, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. <br /> OBSERVATION: The facility has a hazardous waste tank but does not have three years of complete daily tank <br /> inspection records. <br /> -One 500 gallon waste oil tank and one 215 gallon waste antifreeze tank observed with no daily tank inspections <br /> records. <br /> The following were observed in the lube express shop: <br /> -One 600 gallon waste oil tank observed with daily tank inspection records, records end on August. <br /> Note: Operator could not provide any current or previous records when asked by the inspector. <br /> REGULATION GUIDANCE: <br /> (a)The owner or operator shall inspect,where present, at least once each operating day: <br /> (1)overfill/spill control equipment(e.g.,waste-feed cutoff systems, bypass systems, and drainage systems)to <br /> ensure that it is in good working order; <br /> (2)the aboveground portions of the tank system, if any, to detect corrosion or releases of waste; <br /> (3)data gathered from monitoring equipment and leak-detection equipment, (e.g., pressure and temperature <br /> gauges, monitoring wells)to ensure that the tank system is being operated according to its design; <br /> (4)the construction materials and the area immediately surrounding the externally accessible portion of the tank <br /> system including secondary containment structures(e.g., dikes)to detect erosion or signs of releases of hazardous <br /> waste (e.g.,wet spots, dead vegetation); and <br /> (5)for uncovered tanks,the level of waste in the tank, to ensure compliance with section 66265.194(b)(3). <br /> (c)The owner or operator shall document in the operating record of the facility an inspection of those items in <br /> subsection (a)of this section. <br /> CORRECTIVE ACTION: Immediately start conducting and documenting complete daily hazardous waste tank <br /> inspections. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a repeat violation, Class II. <br /> FA0013604 PR0517823 SCO01 12/05/2019 <br /> EHD 22-02 Rev.9/20/2019 Page 10 of 16 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.