Laserfiche WebLink
SAN" J D�l+ �� I 1411" Environmental Health Department <br /> COUNTY�l <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ATS MANTECA 1 17333 S COMCONEX RD MANTECA Aril 29 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 401 CCR 66262.34(d)(2) Failed to store hazardous waste in a container that is in good condition. <br /> Approximately 65 one gallon paint cans observed on the south side of the property with rusty can conditions. <br /> Hazardous waste shall be stored in a container that are in good condition. Immediately transfer all hazardous wastes <br /> into containers that are in good condition or have hazardous wastes properly disposed of by a licensed hazardous <br /> waste hauler under a proper manifest. <br /> Please provide disposal records for these paint cans. <br /> This is a Class II violation. <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> - 1 black 55 gallon container of used metal oil filters observed with lid not closed (storage area) <br /> - 1 black 55 gallon container of used oil observed with lid not closed (storage area) <br /> - 1 black 5 gallon bucket of used oil with no lid (next to used oil tank) <br /> - 1 orange 5 gallon bucket of used oil with no lid on the north end of the shop <br /> - 1 metal container with used oil and metal parts near the dumpster <br /> - 1 white cut in half container with used oil observed with no lid in the south corner of the shop <br /> - 1 yellow 55 gallon container with used oil observed with no lid in the center of the shop <br /> All hazardous waste containers shall be closed at all times except when adding or removing waste. Immediately <br /> close these containers and ensure all hazardous waste containers are closed when not adding or removing waste. <br /> Please provide lids for these containers and make sure to properly transfer contents to an appropriate waste container. <br /> This is a minor violation. <br /> 502 CCR 66262.34(d)(2)Tank system inspections of discharge systems, monitoring equipment, and tank levels not done <br /> daily. <br /> Daily inspections of the discharge systems, monitoring equipment, and tank levels were not performed. 10,000 gallon <br /> white tank of used oil, approximately 1200 gallon green tank of unknown contents, Immediately begin to conduct <br /> daily inspections of the discharge systems, monitoring equipment, and tank levels for all tanks containing hazardous <br /> waste. <br /> Inspector provided daily tank inspection spread sheet, please begin doing daily tanks inspections. <br /> This is a minor violation. <br /> FA0011214 PR0518213 SCO01 04/29/2019 <br /> EHD 22-01 Rev.09/27/2018 Page 7 of 8 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />