Laserfiche WebLink
S A N J D AR I N Environmental Health Department <br /> (..)4J ,ti+ 1 Y <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Morada Forklift 4283 N WILSON WAY, STOCKTON October 15, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 CCR 66262.12 Managed a hazardous waste without an identification number. <br /> OBSERVATION: This business does not have a hazardous waste ID number in the California Department of Toxic <br /> Substances Control (DTSC)database. <br /> REGULATION GUIDANCE: A hazardous waste generator shall not treat, store, dispose of,transport or offer for <br /> transportation, hazardous waste without having received an Environmental Protection Agency(EPA) Identification <br /> (ID) Number.A State EPA ID number is required for generators of less than 100 kg RCRA hazardous waste per <br /> month, less than one kg of acutely hazardous waste per month or any amount of non-RCRA hazardous waste. ID <br /> numbers are unique to a business and site location. <br /> CORRECTIVE ACTION: Go to the DTSC web site at https://dtsc.ca.gov/apply-for-hazardous-waste-epa-id-number/ <br /> to obtain a State ID number. Immediately apply for your ID number and submit evidence to the San Joaquin <br /> County Environmental Health Department within 30 days. <br /> This is a minor violation. <br /> 104 CCR 66262.34(d)(2)No modified contingency plan. <br /> OBSERVATION: A complete modified contingency plan was not posted at the facility. <br /> REGULATION GUIDANCE: The business operator must post the following information next to telephones or in <br /> areas directly involved in the generation and accumulation of hazardous waste: the name and emergency <br /> telephone number of the emergency coordinator, the location of fire extinguishers and spill control material, and the <br /> telephone number of the fire department unless the facility has a direct alarm. <br /> CORRECTIVE ACTION: A modified contingency plan form was provided and information for emergency <br /> coordinator, alternate emergency coordinator, Location of fire extinguisher, spill equipment and phone numbers for <br /> the fire department were completed while inspector was on site. The violation was corrected during the inspection <br /> by Owner Dustin Diaz while inspector was on site. No further action is required to correct this violation. <br /> This is a minor violation. <br /> 119 HSC 25404(e)(4) Failed to report program data in the California Environmental Reporting System (CERS). <br /> OBSERVATION: This business's hazardous waste activities have not been reported on the California Electronic <br /> Reporting System (CERS)website. <br /> REGULATION GUIDANCE: Each regulated business shall report program data electronically on the CERS <br /> website. <br /> CORRECTIVE ACTION: A CERS account was created and a submittal for facility information that this facility does <br /> generated hazardous waste was submitted by the Owner Dustin Diaz while inspector was on site. No further action <br /> is required to correct this violation. <br /> This is a Class II violation. <br /> FA0014023 PR0518636 SCO01 10/15/2019 <br /> EHD 22-01 Rev.9/20/2019 Page 4 of 7 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />