My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
I
>
INDUSTRIAL
>
1010
>
2200 - Hazardous Waste Program
>
PR0518741
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 4:25:17 PM
Creation date
6/30/2020 1:01:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518741
PE
2220
FACILITY_ID
FA0010456
FACILITY_NAME
THATCHER COMPANY OF CALIFORNIA INC
STREET_NUMBER
1010
STREET_NAME
INDUSTRIAL
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
17728053
CURRENT_STATUS
01
SITE_LOCATION
1010 INDUSTRIAL DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
346
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Data Qualifiers and Definitions <br /> Qualifiers <br /> A See Report Comments, <br /> B Analyte was present in an associated method blank. <br /> Bl Analyte was present in a sample and associated method blank greater than MDL but less than RDL. <br /> BQ1 No valid test replicates.Sample Toxicity Is possible.Best result was reported. <br /> BQ2 No valid test replicates. <br /> BQ3 No valid test replicates.Final DO Is less than 1.0 mg/L.Result may be greater. <br /> B04 Minor Dissolved Oxygen loss was observed In the blank water check,however,the LCS was within criteria,validating the batch. <br /> BQ5 .Minor Dissolved Oxygen loss was observed In the blank water check. - <br /> c Possible laboratory contamination. <br /> D RPD was not within control limits,The sample data was reported without further clarification. <br /> 01 Lesser amount of sample was used due to Insufflclent amount of sample supplied. <br /> D2 Reporting limit Is elevated due to sample matrix. Target analyte was not detected above the elevated reporting limit. <br /> D3 Insufficient sample was supplied for TCLP. Client was notified. TCLP was performed per the Client's instructions. <br /> DW Sample result is calculated on a dry weigh basis. <br /> E Concentration is estimated because it exceeds the quantification limits of the method. <br /> I The sample was read outside of the method required Incubation period. <br /> IR Inconclusive Result, Leglonella Is present,however,there is possible non-specific agglutination preventing specific identlflcation. <br /> J Reported value is estimated <br /> L The laboratory control sample(LCS)or laboratory control sample duplicate(LCSD)was out of control limits. Associated sample <br /> data was reported with qualifier. <br /> L2 LCS did not meet recovery criteria, however,the MS and/or MSD met LCS recovery criteria,validating the batch. <br /> - M The matrix spike(MS)or matrix spike duplicate(MSD)was not within control limits due to matrix interference.The associated <br /> - -LCS and/or LCSD was within control limits and the sample data was reported without further clarification. <br /> M1 The matrix spike(MS)or matrix spike duplicate(MSD)is not within control limits due to matrix interference. <br /> M2 The matrix spike(MS)or matrix spike duplicate(MSD)was not within control limits. The associated LCS and/or LCSD was not <br /> within control limits. Sample result is estimated. <br /> N1 Sample chromatography does not match the specified TPH standard pattern. <br /> NC The analyte concentration In the sample exceeded the spike level by a factor of four or greater,spike recovery and limits do not <br /> apply.. <br /> P Sample was received without proper preservation according to EPA guidelines. <br /> P1 Temperature of sample storage refrigerator was out of acceptance limits.. <br /> P2 The sample was preserved within 24 hours of collection in accordance with EPA 218.6. <br /> P3 Per Client request,sample was composlted for volatile analysis. Sample compositing for volatile analysis is not recommended <br /> due to potential loss of target analytes.Results may be biased low. <br /> Q1 Analyte Calibration Verification exceeds criteria.The result is estimated, <br /> Q2 Analyte calibration was not verified and the result was estimated. <br /> Q3 Analyte initial calibration was not available or exceeds criteria,The result was estimated. <br /> S The surrogate recovery was out of control limits due to matrix interference.The associated method blank surrogate recovery <br /> was within control limits and the sample data was reported without further clarification. . <br /> S1 The associated surrogate recovery was out of control limits;result Is estimated. <br /> S2 _ The surrogate was diluted out due to the presence of high concentrations of target and/or non-target compounds.Surrogate _ <br /> recoveries in the associated batch QC met recovery criteria. <br /> S3 Internal Standard did not meet recovery limits.Analyte concentration is estimated. <br /> T- Sample was extracted%analyzed past the holding time. <br /> T1 Reanalysis was reported past hold time due to failing replicates in the original analysis(BOD only). <br /> T2 Sample was analyzed ASAP but received and analyzed past the 15 minute holding time. <br /> T3 Sample received and analyzed out of hold time per client's request. <br /> T4 Sample was analyzed out of hold time per client's request. <br /> TS Reanalysis was reported past hold time. The original.analysis was within hold time,but not reportable. <br /> T6 Hold time is Indeterminable due to unspecified sampling time. <br /> T7 Sample was analyzed past hold time due to Insufficient time remaining at time of receipt. - - <br /> Definitions <br /> DP Dilution Factor <br /> MDL Method Detection Limit. Result is reported ND when it is less than or equal to MDL. <br /> ND Analyte was not detected or was less than the detection limit. <br /> NR Not Reported, See Report Comments. <br /> RDL -Reporting Detection Limit <br /> Tic Tentatively Identified Compounds <br /> Analytical Results Report Enl th,allioy"I <br /> 93952-01 Lab Request 409405, Page 3 of 3 Analytical,LLC <br />
The URL can be used to link to this page
Your browser does not support the video tag.