Laserfiche WebLink
Periodic Integrity Test Certificate <br /> P . O . Box 1289 . . . . . . . . Waterford, CA 95386 Telephone : (209) 9690851 <br /> Email : spc:co "', I hotinail . com <br /> Clients Lodi Chrysler-Dodge-4eeymRam Contact : Weston . Boedin%, Parts & Svc. Director <br /> Address : 1255 So. I3eckmaia . Rd.. Phone No. : 209-263-3999 <br /> City/State/Zip ; Lodi, CA. 95240 Date of Test: 1-30-2019 <br /> Product Stored : Waste Coolantma <br /> Tank Information (Brand/gallonage/Fuel Stored/UL or other serial#/miscellaneous) <br /> Peabody/130. gals/Waste Coolant/ Double Wali Poly IS0900044CFR�264. 193 compliant/10yrs old(estitnate) <br /> Description of Secondary Containment Integral Secondary Containment. <br /> Date of Test 1-302019 Test Supervisors} Todd McWhorter <br /> METHOD OF PERIODIC INTEGRITY TEST-Primary XX Secondary XX <br /> 1 . Poly Outer Wail Thickness Test (in accordance with ISO 9000/9014 and/or STI SP001 (6th edition)- <br /> readings avg. 7.2mm thickness- Suitable for continued usage <br /> 2 . Inert Gas Blanket <br /> Oras Used; Nitrogen CO2: ; Other (specify) <br /> Air Pressure-Test ; Vacuum Test ; <br /> Initial Reading (document psi/WC readings) Time <br /> End Readings (document psi/WC readings) Time <br /> Duration of Test: %o drop <br /> 3 . Sonar-Test Y. N (document db readings) Duration <br /> 4 . Camera (visual) /interstitial (Result: P/F),,,,_ . <br /> 5 . Hydro-Carboii Sensor (probe) model (Result: P/F) <br /> 6 . Hydrology (Water Column) ( inches of water column readings) <br /> Duration % Drop Results (P/F) <br /> 7 . Other : Inspect Primar Vessel & Secondary containment. CRUM present, no evidence of leaking <br /> product from primary vessel, system accessible for inspection: AST sits within secured lubricants <br /> enclosure. U on inspection , no evidence of seam breaks unctures cracks or other structural damage to the <br /> tank Leak detection is assuredvia inspections of the secondary containment. No evidence of leak nor of <br /> anv product in secondary. PASS <br /> TEST RESULTS <br /> 1st-Stage: <br /> Pass XX Fail_ (quantify) OUTER. WALL THICKNESS= 71nim ON SIDE AVG, SUITABLE <br /> FOR CONTINUED USAGE <br /> .4 "Stage. <br /> Pass XX Fail (quantify) NO VISUAL EVIDENCE OF PRODUCT IN INTERSTICE, OR ANY <br /> OTHER LEAKS <br /> Comments Tank is anchored to concrete floor with steel brackets & Y� bolts data on file <br /> Date of Next Scheduled Periodic Integrity Test 1-30-24 <br /> SPC- Corp Representative <br /> STI SP001 Certiried Inspector No. : AST 135013 <br />