FACILITY_NAME
GILL EXPRESS INC
STREET_NUMBER
1022
Direction
E
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102004
CURRENT_STATUS
01
SITE_LOCATION
1022 E FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 1 ( Continued ) <br /> EXISTING ABOVEGROUND STORAGE TANKS SYSTEM INTEGRITY EVALUATION <br /> Regulatory Citation <br /> NumberA <br /> 22 CCR § 66265. 191 Regulatory Citation Language Facility Compliance <br /> (9) results of a leak test, internal <br /> inspection , or other tank system Visual observations coupled with AST inspection <br /> integrity examination including the type techniques specified in the Steel Tank Institute, <br /> of integrity examination performed (i . e . Standard for the Inspection of Aboveground Storage <br /> ultrasonic, internal examination , Tanks, SP001 , Ern Edition, Issue January 2018 were <br /> volumetric tank test, pipeline pressure utilized to evaluate the integrity of the AST and the <br /> test) . Tank system integrity or leak test secondary containment structure . <br /> (g) requirements must be in compliance The system was observed while operating . No leaks <br /> withal local requirement. Prior to were observed associated with the AST , compressor, <br /> conducting a tank system integrity test <br /> or leak test, contact local agency staff pneumatic pump , and pipes . <br /> for local requirements . The AST , compressor, pneumatic pump , and pipes <br /> ( 10) estimated remaining service life of should be formally inspected for leaks in 5 years from <br /> the tank system based on findings of the date of this report . <br /> subsections 1 through (g) (9) . <br /> NOTE <br /> A: Applicable sections of Title 22, California Code of Regulations, Division 22 , Chapter 15, Article 10, Section 66265. 191 have been cited . <br />