S 11�1N J OAQ U I I N Environmental Health Department <br /> COUNTY <br /> RCRA Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 3 Us truck&auto plaza 1 14749 N Thornton Rd, Lodi December 02, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 512 CCR 66265.192(h) Failure to obtain a reassessment of a tank system within 5 years or as required. <br /> OBSERVATION: This facility has a 1000 gallon used oil hazardous waste tank which has not been reassessed by a <br /> Professional Engineer within the past five years. The tank assessment observed during the inspection was last done <br /> on 1/28/2010. No current reassessment was available for review and the manager, Francisco Avila,was not sure if <br /> another one had been done. <br /> REGULATION GUIDANCE: <br /> The assessment specified in subsection (k)of this section shall be obtained prior to placing a new tank system in <br /> service and shall be kept on file at the facility.This assessment shall be reviewed and certified by an independent, <br /> qualified, professional engineer, registered in California, in accordance with section 66270.11(d), attesting that the <br /> tank system has sufficient structural integrity and is acceptable for the transferring, storing and treating of hazardous <br /> waste.The assessment shall be valid for a maximum period of five (5)years or the remaining service life of the tank <br /> system, as stated in the engineer's assessment,whichever is less. <br /> CORRECTIVE ACTION: Immediately provide the current tank reassessment to the San Joaquin County <br /> Environmental Health Department(EHD). If a tank reassessment has not been done within the last 5 years(or as <br /> required), immediately get a tank reassessment done and provide a copy to the EHD within 30 days. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> OBSERVATION: Hazardous waste containers were observed on-site with incomplete labeling. <br /> Inside the shop: <br /> -One black 55 gallon steel drum containing used oil was missing a hazardous waste label. This label was corrected <br /> during the inspection. <br /> -One black 55 gallon steel drum containing paper filters had a hazardous waste label that was incorrectly labeled as <br /> "metal filters"and was missing the hazardous property. <br /> Outside the shop: <br /> -One black 55 gallon steel drum containing oily water had a hazardous waste label where the contents were <br /> incorrectly labeled as"used absorbent"and the physical property was incorrectly labeled as"solid." The label was <br /> also missing the hazardous property. <br /> REGULATION GUIDANCE: All hazardous waste containers shall be marked with the following information: the <br /> words"Hazardous Waste", name and address of generator, hazardous properties, physical state, composition <br /> (contents), accumulation start date <br /> CORRECTIVE ACTION: Immediately label the containers as required for hazardous waste. Provide a corrective <br /> action statement and supporting documentation to the San Joaquin County Environmental Health Department <br /> (EHD)within 30 days. <br /> This is a repeat violation, Class ll. <br /> FA0000482 PR0519127 SCO01 12/02/2019 <br /> EHD 22-03 Rev.9/20/2019 Page 10 of 12 RCRA Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />