My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013454
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
B
>
4725
>
2600 - Land Use Program
>
PA-2000089
>
SU0013454
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2020 2:20:12 PM
Creation date
7/1/2020 12:38:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013454
PE
2635
FACILITY_NAME
PA-2000089
STREET_NUMBER
4725
Direction
S
STREET_NAME
B
STREET_TYPE
ST
City
STOCKTON
Zip
95206-
APN
17726034
ENTERED_DATE
6/29/2020 12:00:00 AM
SITE_LOCATION
4725 S B ST
RECEIVED_DATE
6/26/2020 12:00:00 AM
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
197
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4-- <br /> PARKING LOT SIGNS <br /> 111 <br /> FASTEN TO LIGHT POLE OR SIGN AS GALV.STEEL Mounting U-p Description: 7 0 - 7 - U N j <br /> CHANNEL POST,WITH 3/8"S/S HEX SCHEDULED CHANEL 1. Panel signs with custom sign faces 1'-0" �_ p N <br /> HEAD BOLT,LOCKWASHER ON FACE �\ POST, PRIME Materials and Construction FULL WIDTH OF LANE L <br /> OF SIGN,LOCTITE ON THREADS, AND PAINT 1. The sign consists of an aluminum sign panel directly attached to an existing light pole.G.C.to verify w/light pole manufacturer that pole U > <br /> DRILL AND TAP TO STEEL POLE. GALV.STEEL BLACK will structurally support sign Q w w <br /> (TWO FASTENERS PER SIGN) CHANEL ° 2. Solid aluminum panel,0.125"thick.Composite materials are not acceptable. <br /> 20'0" POST, PRIME 3. Panel and light pole are drilled and tapped. Panel attaches with two 3/8"hex head bolts,assisted with lock washers and an application of WHITE <br /> A.G. AND PAINT SIDING " Loctite " adhesive. STRIPING <br /> BLACK LOADED 4. The sign shall comply with all local codes.Supports shall be sufficient for secure mounting of the sign. o <br /> BASE 5. All hardware is to be non-corrosive. If additional thickness of material or additional internal bracing is required for secure installation of the S-1 o BLACK <br /> SHIM AS REQ signs or to provide stability to prevent warping such alterations shall be reflected in the shop drawings.Wind loading and durability shall M <br /> 9 P Y p p 9 p 9 9 Y (UNPAINTED . . <br /> FOR PLUMB o "STOP" NOT- <br /> INSTALLATION be taken into account in engineering this sign. SIGN, POST ASPHALT) <br /> c� 6. Graphics and TypographySign graphics are heavy duty 3M vinyl. <br /> 7. Custom graphics and sign face layouts are available from the owner as electronic files. MOUNTED N <br /> 12-0 SIGN AS o 0 6"DIA.STEEL 8. Colors are indicated on the Design Intent Drawings.Additional color and finish specifications are found in the General Specifications. <br /> SCHEDULED / PIPE, FILL WITH Installation: <br /> 220 Norwood Park South <br /> A.G. ti 18"DIA. ti ZD CONCRETE, 1. Locations are generally noted on the attached location plans.The contractor is responsible for field verifying all installation conditions SESuite 201 <br /> CONC. PRIME AND prior to fabrication. Norwood,MA 02062 <br /> BASE PAINT'SAFETY 2. Bottom of sign panel installs varies. (781) 619-9500 <br /> (3,000 PSI) YELLOW' 3. The installation methods and details for each location shall be illustrated in the submitted shop drawings. Final locations will be approved PG 1 <br /> LIGHT POLE on site by the tenant or his representative. - <br /> Submittals: WIDTH OF LANE X V-0" <br /> 1. The following shall be submitted for approval prior to fabrication: WHITE STOP BAR. USE AT ALL STOP SIGN PG-20 �# � <br /> KVIT <br /> V_ <br /> I NOTE: USE AT ALL 2. Electronic shop drawings are acceptable (S-1)LOCATIONS.WHITE PAVEMENT 24'0"X 22'0" <br /> el <br /> HANDICAPPED 3. Color samples to be submitted. STRIPE. + . [+kE <br /> ch � ch J PARKING SPACES WHITE PAVEMENT GRAPHICS-PEDESTRIAN TABLE. t7 <br /> #6 BAR-14" \ a " UNLESS LOCAL NOTES: USE AT CROSSWALKS AT HIGH TRAFFIC AREAS PER <br /> ORDINACES REQUIRE SITE(EX. MAIN ENTRANCE) WHITE STRIPING ON <br /> 1.VERIFY POST SIZE WITH SIGN MOUNTING HEIGHTS. RAISED ASPHALT TABLE. r <br /> FRONT/REAR ELEVATION SIDE ELEVATION °° LONG EACH OTHERWISE 2.THESE DETAILS PROVIDE INTENT ONLY. FINAL POST& 3 PAVEMENT GRAPHICS DETAILS <br /> WAY THRU CONNECTIONS SHALL BE SIZED MEETING LOCAL DOT STANDARDS. EXPIRES <br /> PIPE. Al2.oa 118"=1'-0" Lip 001 <br /> SIGN AT SITE LIGHT POLE SIGN IN LANDSCAPED ISLAND SIGN POST MOUNTED AT PAVED AREAS OF <br /> Post and Panel Signs Mounting U-1e, U-1c, U-2 <br /> Description: "ADA"BLUE "ADA"BLUE <br /> 1. Post and panel signs with standard sized DOT and custom sign faces BACKGROUND BACKGROUND WITH VINYL GRAPHICS GENERAL NOTES <br /> Materials and Construction: WITH WHITE WHITE SYMBOL <br /> 1. The sign consists of an aluminum sign panel on a 2"square steel post SYMBOL <br /> 2. Panel conforms to MUTCD specifications.Solid aluminum, not less than 0.090"thick.Composite materials are not acceptable. DOOR SIGNS: <br /> PROVIDE 1 1/2" 3. Post:2"square steel post, 12 ga,7/16"perforations on 1"centers,four sides,approx 12'o/a SEE DOOR SIGN PLACEMENT DETAIL ON THIS SHEET <br /> STEEL ANGLE 4. The sign shall comply with all local codes.Supports shall be sufficient for secure mounting of the sign. FOR MOUNTING HEIGHTS. <br /> CROSS BRACES 5. All hardware is to be non-corrosive. If additional thickness of material or additional internal bracing is required for secure installation of the signs or to provide stability to prevent <br /> warping such alterations shall be reflected in the shop drawings.Wind loading and durability shall be taken into account in engineering this sign. FOR ALL <br /> 6. Graphics and Typography 4N N-CONNECTICU o SPECIFICATIONS: <br /> 7. All signs indicated"DOT"shall conform to the current Manual on Uniform Traffic Control Devices from the Federal Highway Administration. PROJECTS SEE WORLDWIDE REAL ESTATE SIGNAGE STANDARDS(REV. ~ <br /> 8. Sign graphics are heavy duty 3M reflective vinyl. REMOVE THIS - 10)FOR COLOR GENERAL NOTES AND ADDITIONAL SIGNAGE J <br /> 9. Custom graphics and sign face layouts are available from the owner as electronic files. COLORS. <br /> 10. Colors are indicated on the Design Intent Drawings. NOTELi <br /> Installation: 4'-0" <br /> 0 1. Locations are generally noted on the attached location plans.The contractor is responsible for field verifying all installation conditions prior to fabrication. 4'- DESCRIPTION: <br /> ' 2. Mounting U-1e shall be used in for signs in compacted earth;mounting U-1c shall be used for signs on concrete paving. o CUSTOM CUT VINYL GRAPHICS,ATTACHED TO FIRST Q <br /> °O U. <br /> 3. Mounting U-1e provides a 36"mounting tube(2'/4'square steel post)driven to 1"to 2"above grade.The mounting tube is paired with an 18"breakaway support tube(2'/z"square steel PG-17 PG-18 SURFACE OF EXTERIOR GLASS. <br /> post).The sign post sinks to the base of the anchor tube and fastens to the anchor tube and breakaway support with an angle bolt. <br /> 4'-0"X 4'-0" 4'-0"X 6-5 1/2" 7- <br /> 4. Mounting U-1c provides a pedestal base married to the 2"post.The base is shimmed for plumb installation of he post and panel.The base fastens to the concrete paving with masonry PAVEMENT GRAPHICS PAVEMENT GRAPHICS-VAN GRAPHICS AND TYPOGRAPHY: O � <br /> anchors according to the base and anchor manufacturers'specifications. LU O <br /> STANDARD ACCESSIBLE ACCESSIBLE PARKING SPACE. SIGN GRAPHICS ARE HEAVY DUTY'3M'VINYL. LOGO IS A HIGH <br /> 5. Typical sign panel installs 7'0"above grade.The post extends to within 2"of the top of the sign panel. Installation shall be plumb,level and straight. PARKING SPACE.USE AT ALL USE AT ALL VAN ACCESSIBLE RESOLUTION DIGITAL PRINT ON PERMANENT ADHESIVE W LL_ <br /> 6. Mounting U-2 provides two pole support similar to mounting U-1 e.Additionally, U-2 requires cross bracing of structural angle on the back of the sign face. ACCESSIBLE PARKING SPACES. PARKING SPACES.WHITE SYMBOL PRESSURE SENSITIVE VINYL SUBSTRATE WITH LUSTER OVER Q!� J <br /> 7. Top of the U-2 mounted sign installs 60"above grade. Installation shall be plumb,level and straight. WHITE SYMBOL WITH BLUE WITH BLUE BACKGROUND,AND LAMINATE,CUT TO SHAPE FROM VECTOR FILE.COPY IS Q <br /> 8. The installation methods and details for each location shall be illustrated in the submitted shop drawings. Final locations will be approved on site by the owner or his representative. ( ( MATTE WHITE VINYL. <br /> FRONT BACK BACKGROUND BLACK INDICATES WHITE TEXT BLACK INDICATES Q � / <br /> Submittals: ASPHALT). ASPHALT). [ � m U <br /> 1. The following shall be submitted for approval prior to fabrication: INSTALLATION: �•/ <br /> GALV.STEEL 2. Electronic shop drawings are acceptable V) Z <br /> CHANEL POST, 3. Three 6"x 6"vinyl samples of each sign face color 4 PAVEMENT GRAPHIC DETAILS LOCATIONS ARE GENERALLY NOTED ON THE ATTACHED �/LOCATION PLANS.THE CONTRACTOR IS RESPONSIBLE FOR Lo PRIME AND 4. See General Construction and Installation Specifications for additional submittals. Al2.o4 114"=1'-0" O <br /> FIELD VERIFYING ALL INSTALLATION CONDITIONS PRIOR TO � � � <br /> PAINT BLACK FABRICATION.THE INSTALLATION METHODS AND DETAILS FOR <br /> EACH LOCATION SHALL BE ILLUSTRATED IN THE SUBMITTED 0U <br /> � SITE SIGN MOUNTING DETAILS SHOP DRAWINGS. FINAL LOCATION WILL BE APPROVED ON SITE O <br /> BY THE TENANT REPRESENTATIVE. W <br /> Al2.04 1/4"-V-0" PAVEMENT GRAPHIC NOTES: N <br /> SUBMITTALS: O <br /> 1. TWO COAT APPLICATION REQUIRED FOR ALL THE FOLLOWING SHALL BE SUBMITTED FOR APPROVAL PRIOR <br /> PAVEMENT GRAPHICS. <br /> 42" 12" 6" 12" 42" 2. REFER TO CIVIL FOR PAINTED GRAPHIC ARROWS TO FABRICATION-(3)SETS OF SHOP DRAWINGS AND(3)6"X6" <br /> AND ADDITIONAL PAVEMENT GRAPHIC CRITERIA. VINYL SAMPLES OF EACH SIGN FACE COLOR.SEE GENERAL O <br /> CONSTRUCTION AND INSTALLATION SPECIFICATIONS FOR <br /> ADDITIONAL SUBMITTALS. <br /> M <br /> PAVEMENT PAINT SIGNAGE GENERAL NOTES <br /> 1. FINAL QUANTITIES SHALL BE COORDINATED AND VERIFIED IN FIELD. <br /> clj <br /> NOT <br /> oTA1/PP1 WHITE 2. ADDITIONAL SIGNAGE NOT SHOWN ON GRAPHICS PLAN MAY BE <br /> co <br /> TA2/PP2 RED (PANTONE 485C) REQUIRED PER LOCAL CODE AND/OR AHJ.SUB-CONTRACTOR SHALL <br /> TA3/PP3 BLUE (PANTONE 294) COORDINATE WITH LOCAL AHJ AND PROVIDE AS REQUIRED. <br /> NOT �2 USE <br /> 3. MOUNT SIGNAGE ACCORDING TO LOCAL CODES. <br /> TA4/PP4 GREEN (PANTONE 342) 4. ALL PERMANENT SIGNANGE TO ACCESSIBLE AREAS TO HAVE RAISED <br /> co TA5/PP5 YELLOW (PANTONE 116) BRAILLE CHARACTERS PER ANSI 117.1-2003 <br /> 5. TYPICAL SIGN FONT IS SET IN ARIAL. <br /> ao NOTE:TWO COAT APPLICATION REQUIRED FOR ALL PAVEMENT GRAPHICS. 6. SEE DOOR SCHEDULE FOR DOOR SIGNAGE REQUIRED TEXT. <br /> 0USED <br /> M <br /> V <br /> N <br /> PG-8 <br /> = 10'-0"X F-0" <br /> Ll N <br /> WHITE PAVEMENT GRAPHICS-LEFT <br /> OR RIGHT TURN ARROW.USE TO <br /> 4"WIDE X 60'-0" <br /> 24" ' 27" 12" 27" 3" 24" INDICATE TURNING LANES. LONG PAINTED <br /> (BLACK INDICATES ASPHALT) STRIPE(WHITE), <br /> ALIGN WITH <br /> PG-9 DRIVER'S SIDE EDGE <br /> SEE PLANOF DOCK DOOR AND <br /> 10'-0"X 12'-0" 12"STRIPING ,r---12" LOUVER OPENING. <br /> WHITE PAVEMENT GRAPHICS-LEFT, AT CROSSWALK !% STRIPING AT TYPICAL EACH <br /> 12" 6 12" 42" ! i ACTIVE DOCK AND � <br /> STRAIGHT OR RIGHT TURN ARROW. (WHITE) CROSSWALK LOUVER POSITION. o <br /> USE TO INDICATE TURNING LANES. (YELLOW) <br /> (BLACK INDICATES ASPHALT) / �, 4"STRIPING AT <br /> v) <br /> ACCESSIBLE -----SEE BUILDING PLAN Z <br /> / PARKING FOR DOCK DOOR v <br /> N NUMBERS. w o <br /> �9 <br /> (BLUE) Lo COORDINATEnof <br /> NUMBERS WITH z° <br /> =0o TN /J120 <br /> TENANT OF TRAILER <br /> N 0 T <br /> C �K I �n D PARKING. <br /> Co `r -Coy 2 -6 Designed B.S.R. <br /> v Cl) NOTNOT <br /> Drawn B.S.R. <br /> U U <br /> 0 0 o Reviewed S.M.K. <br /> `' oScale AS INDICATED <br /> M co <br /> x o Project No. 1902145 <br /> N � � <br /> USEr,USED <br /> Z, Date 05/15/2020 <br /> z SE <br /> - - 25 <br /> ° <br /> 0 DM CAD File: <br /> N <br /> DN 190214501 <br /> 3 <br /> 13'-6" <br /> o Title <br /> Lo <br /> N 24" " 27" 12" 12" 27" 3" 24" (VARIES-SEE SITE PLAN) <br /> o <br /> 12" 12" 12" DETAIL <br /> Z <br /> PG-10 PG-11 PG-12 PG-14 SHEET <br /> "STRIPING OUTLINE AND HATCH FILL AT <br /> o <br /> PG-5 PG 6L(PG 6R OPP.) PG 7L(PG 7R OP P.) 4"STRIPING OUTLINE AND FILL AT 45 DEGREES. WHITE 12"STRIPING OUTLINE AND HATCH YELLOW 12WHITE 54"X T-6"(24"TALL LETTERING) <br /> 8 0 X 10 0 8 0 X 8 0 8 0 X 12 0 PAVEMENT GRAPHICS-TRAFFIC ISLAND. FILL AT 36"O.C.PAVEMENT GRAPHICS- 36"O.C.PAVEMENT GRAPHICS-DRIVER ENTRANCE, PAVEMENT GRAPHICS TRAILER SPACE <br /> USE TO PROHIBIT VEHICLE TRAVEL AND PARKING. PEDESTRIAN CROSSWALK.USE TO USE TO DIRECT DRIVER ENTRANCE IN DOCK FIELD. NUMBERING. USE TO LABEL TRAILER <br /> WHITE PAVEMENT GRAPHICS- WHITE PAVEMENT GRAPHICS- WHITE PAVEMENT GRAPHICS- YELLOW AT NO TRAFFIC,BLUE AT ACCESSIBLE POSITION IN TRUCK COURT TO CORRESPOND WITH SPACES.TYPICAL ALL TRUCK DOCK <br /> o <br /> STRAIGHT ARROW.USE TO DIRECT LEFT TURN ARROW.USE TO STRAIGHT OR RIGHT TURN ARROW. PARKING SPACES,WHITE AT VENDOR PARKING INDICATE PEDESTRIAN CROSSING. THE LOCATION OF THE TRUCKERS LOUNGE AND SPACES. (BLACK INDICATES ASPHALT). Sheet No. <br /> TRAFFIC AT ONE-WAY DRIVE AISLES. INDICATE TURNING LANES. USE TO INDICATE TURNING LANES. (BLACK INDICATES ASPHALT).INCLUDE AT SEE PLAN FOR WIDTH OF CROSSWALK TRUCKERS ENTRY POINTS.SEE PLAN FOR WIDTH SEE PLANS FOR DOCK DOOR NUMBERS. <br /> ° EMERGENCY EXITS INTO THE PARKING LOT AT ALL (BLACK INDICATES ASPHALT) OF CROSSWALK(BLACK INDICATES ASPHALT) COORDINATE NUMBERS WITH TENANT <br /> (BLACK INDICATES ASPHALT) (BLACK INDICATES ASPHALT) (BLACK INDICATES ASPHALT) PARKING SPACES THAT IMPEDE DIRECT ACCESS TO OF TRAILER PARKING. DN = 1 <br /> Z THE THOROUGHFARE. <br /> 2 PAVEMENT GRAPHIC DETAILS <br /> o N <br /> Al2.04 1/4"=1'-0" <br /> x <br /> ®2020 BL COMPANIES,INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON,FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES. <br />
The URL can be used to link to this page
Your browser does not support the video tag.