Laserfiche WebLink
The following is an itemized list of hazardous waste violations that have not been <br /> addressed for JAAS AUTO SERVICE as of July02 , 2020 . <br /> Open violations from November 30, 2018 inspection <br /> Violation #502 - Failed to comply with new hazardous waste tank system assessment requirements . <br /> Facility does not have a tank assessment for the 500 gallon used oil tank . The owner or operator of a hazardous <br /> waste tank shall obtain a written assessment reviewed and certified by an independent, qualified , professional <br /> engineer, registered in California attesting that the system has sufficient structural integrity, is acceptable for the <br /> transferring , storing , and treating of hazardous waste , and that the tanks and containment system are suitably <br /> designed . Immediately have an assessment prepared for the 500 gallon used oil tank . Submit a schedule showing <br /> when this will be accomplished to the EHD and submit a copy of the assessment to the EHD for review. <br /> ❑ This violation was corrected ElThis violation will be corrected by (date) . <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #507 - Failed to conduct daily inspections of hazardous waste tank system and maintain records <br /> onsite . <br /> Inspections of the hazardous waste tank system are not performed and documented . The following items are <br /> required to be inspected at least daily: <br /> 1 . overfill/spill control equipment; <br /> 2 , aboveground portions of the tank system to detect corrosion or releases of water; <br /> 3 . data gathered from monitoring and leak-detection equipment; <br /> 4 , outside areas of the tank system including secondary containment to detect erosion or signs of releases of <br /> hazardous waste ; <br /> 5 , for uncovered tanks , the level of waste in the tank . <br /> Immediately begin required inspections of the hazardous waste tank system , and document the items inspected . <br /> Submit a copy of the inspection log for the next 30 days to the EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> i <br /> I <br /> j Page 7 of 9 <br /> I <br />