ga
<br /> SUMMARY OF THE CORRESPONDINWALIFORNIA,HEALTH AND SAFETY CO ECTIONS ARE PROVIDED BELOW.
<br /> THIS SUMMARY PAGE LISTS THE GENERAL REQUIREMENT FOR EACH NU ERED ITEM IN THE INSPECTION
<br /> REPORT. THE DEPARTMENT MAY CITE ADDITIONAL SECTIONS AS APPLICABLE.
<br /> REQUIREMENTS MARKED WITH AN ASTERISK ARE SPECIFIC TO TEMPORARY BODY ART FACILITIES
<br /> Cleaning and Sterilization reprocessed before use. Only clean calipers shall
<br /> 1. Sterilization shall be accomplished pursuant to the be used. Disposable, single-use, presterilized stud
<br /> procedures established by steam autoclave. and clasp only used for piercing ear. §119309,
<br /> §119315, §119321 §119310, §119311, §119315
<br /> 2. Instruments or other reusable items shall be Practitioner Health and Hygiene
<br /> washed, disinfected, packaged, and sterilized after 9. No food, drink, tobacco product, or personal effects
<br /> each procedure. Packages shall contain either an are permitted in the procedure area. §119309
<br /> integrator or temperature indicator and shall be 10. Practitioner shall wash hands in approved manner
<br /> labeled with name of instrument, date, and initials. before procedure&when soiled. §119301, §119308
<br /> Used, reusable instruments to be stored in liquid 11. Hand washing sink in procedure area is supplied,
<br /> until cleaned and sterilized. An instrument or has potable,warm water and is accessible. §119314
<br /> reusable item that does not come into contact with
<br /> non-intact skin shall be washed, scrubbed and *Practitioners shall have direct access to hand washing facilities
<br /> decontaminated after each procedure. §119309 (both permanently plumbed&individual stations). §119317,
<br /> §119315 §119318
<br /> 3. Sterilizer shall be used and maintained according to 12. Practitioner shall use appropriate personal protective
<br /> manufacturer's directions. §119315 equipment, including gloves, aprons, lap pads, etc.
<br /> 4. Autoclave shall be spore tested after initial Gloves shall be worn throughout and if removed,
<br /> installation, major repair, and at least once per hand hygiene performed before new gloves are
<br /> month. Test results shall be recorded in a log. This donned.While branding appropriate protective face
<br /> log shall also contain date, contents, exposure time filter masks shall be worn by practitioner and client.
<br /> and temperature, results of Class V integrator for 119308, 119309
<br /> every cycle/load and'when the biological test is *Eye wash station available for artist's use. §119318
<br /> positive—show a negative test before continued use
<br /> &shall be kept on site for two years. §119315 Customers/Clients
<br /> 5. Decontamination/sterilization area is separated from 13. Branding shall not be done with another client in the
<br /> procedure areas &supplied with a sink(hot and cold procedure area. §119309
<br /> water, liquid soap&paper towels in a wall-mounted
<br /> dispenser)that is readily accessible to practitioner,. 14. Clients shall be at least 18 years of age to receive a
<br /> contains lined waste containers&sharps containers. tattoo, permanent cosmetics application, a branding
<br /> Animals are not allowed. 119314 or body piercing (unless piercing in the presence of
<br /> parent or guardian). §119302
<br /> *Decontamination area shall be separated from procedure areas 15. Skin shall be washed before shaved. Immediate)
<br /> by at least 5 feet or cleanable barrier. §119318 prior to performing the body art, client's skin shall be
<br /> 6. A body art facility lacking a cleaning room & prepared with an antiseptic solution, antimicrobial or
<br /> sterilization equipment shall use only disposable, microbicide, according to manufacturer's
<br /> single-use, pre-sterilized instruments&maintain instructions. §119308
<br /> records of purchase, use, procedures(include name 16. Client's consent form and questionnaire includes all
<br /> of practitioner&client&procedure date). Keep required components. §119303
<br /> records for at least 90 days. §119315 17. After care instructions includes all required
<br /> *Adequate back up supplies available and stored appropriately components and are provided to client. §119308
<br /> for purchase by practitioners§119318 Tattoo and Permanent Cosmetic Machine Safe and
<br /> 7. Sharps containers are within arm's reach, labeled & Sanitation
<br /> disposed of by approved method. Sharps waste 18. The machine shall be of a safe design with
<br /> includes, needles&needle bars, hand tools if removable parts between the tip and motor housing
<br /> needle is part of unit(used to insert pigment), to prevent backflow into the enclosed parts of the
<br /> razors etc. 119311 119314 motor housing. §119311
<br /> E"Shcontainers provided at each booth.Licensed medical 19. Wash and disinfect reusable instruments(machines,
<br /> posal company retained for sharps pickup.§119318 clip cords, etc.). §119308, §119309, § 119311
<br /> 8. Jewelry, tattoo&piercing equipment shall be 20. Grommets and elastic bands shall be discarded
<br /> sterilized prior to use. Sterile packs shall be immediately upon completion of the procedure.
<br /> evaluated and if the integrity of a pack is §119311
<br /> compromised the pack shall be discarded or
<br /> Continued on back of page 2
<br />
|