Laserfiche WebLink
Body Art Inspectiteport Date: <br /> San Joaquin County Environmental Health Department Program <br /> ` 1868 E.Hazelton Ave.,Stockton,CA 95205 Record: <br /> (209)468-3420 <br /> .. F•`'• www.slogv.org/ehd Program <br /> Element: <br /> PR Number PRACTITIONER/ARTIST NAME PR Number PRACTITIONERIARTIST NAME <br /> Teri L.Turrentine-Eisert-permit exp 6/30/14,BBP <br /> PR0538733 posted <br /> Observations and Corrective Actions: <br /> 1. Each sterilization load shall be monitored with mechanical indicators for time, temperature and pressure, Sterilization shall be <br /> accomplished by steam autoclave, manufactured for the sterilization of medical instruments, and pass a Class V integrator test. <br /> HSC 119315(b) <br /> 3. Sterilizer shall be loaded, operated, decontaminated, and maintained according to manufacturer's recommendations. HSC <br /> 119315(b) <br /> 4. Sterilizer shall be spore-tested after initial installation, after major repair, and at least once per month. A written sterilization <br /> shall be maintained for 3 years. The log shall include spore-test results each sterilization cycle, date, contents, exposure time and <br /> temperature, results of the Class V integrator for every cycle/load, and evidence of a acceptable spore test before reuse of the <br /> sterilizer after a failed spore-test. HSC 119315(b) <br /> 5. Decontamination and sterilization areas shall be separated from procedure areas by a space of at least 5 feet or by a <br /> cleanable barrier and equipped with a sink with hot and cold running water, containerized liquid soap, and single use paper <br /> towels dispensed from a wall-mounted, touchless dispenser that is readily accessible to practitioner. HSC 119314(c) <br /> 6. A facility that uses single use instruments shall maintain record of purchase, log of procedures, names of practitioner and <br /> client, date of procedure, instruments used, and written evidence from the manufacture that the instruments have undergone <br /> sterilization. The record of purchase, evidence of sterilization, type and number of instruments used shall be maintained for a <br /> minimum of 90 days after use. HSC 119315(f) <br /> 18. The facilities client consent form and medical questionnaire must include all of the information listed in Form B, and are <br /> available for inspection. HSC 119303 <br /> 32. A body art facility shall have floors, walls, and ceilings that are smooth, nonabsorbent, free of open holes, and washable. <br /> The body art facility shall be free of insect and rodent infestation. The procedure area must be separated, by a wall, ceiling to <br /> floor, from nail and hair activities and be separated from all business not related to body art. Approval of co-located body art <br /> facilites are at the discretion of the LEA. A procedure area must be equipped with adequate light to perform a procedure. Each <br /> Mur-6 area ll have tainers. HSC 119314& 119317 <br /> 35. Operation and employee training records shall be maintained for 3 years and made available for inspection. A written <br /> Infection Prevention and Control Plan (IPCP) shall be maintained, followed and updated. HSC 119313 <br /> Reinspecion on/about: A reinspection fee of$130 per hour may be charged. Page 2 of 3 <br /> EH-03/2015 <br />