Laserfiche WebLink
* L;RXX t iEA(EO-Sterilization Batch Report) <br /> ;hamber NoXIMA-9:U17-02-28/CE Sterilization No. Tclffi#t-ld: JLWX20170228 Date RM: 17-2-28 Order OE C: 1 <br /> 4rticle Name Production No Specification Quantity Remark Parameters During Sterilization Cycle Required Actual <br /> E Cartridges 17-02 20CTN X AiL kChamber Temperature while Sterilization('C) 50.0 Min 49.3 Max 50.6 <br /> kffii1-10jChamber Preesure while Sterilization(kPa) Min Min -7 3 Max _1.6 <br /> X-MR.A€Chamber Humidity while Sterilization(%RH) NA Min 46.9 Max 55.2 <br /> XMittN1Exposure Time(min) 480 480 • <br /> NAPre-Vacuum Value(kPa) -45.0 -45.1 <br /> )AI W1.KJi4M St Pressure Amplitude while Humidifying((kPa) 2.0 2.0 <br /> t1UARrah-j7 Pressure Changed while Humidifying(kPa) NA B -44.5 E -42.5 <br /> MI PM)J%APressure Amplitude while EO Injection(kPa) 99.0 40.9 <br /> briP5 Ora 6))Pressure Changed while EO Injection(kPa) NA B -42.5 E -1.6 <br /> 1JUA:f'M:Weight of EO used(kg) <br /> Sterilization Phase Start Time End Time Actual Time Sterilization Information PAidease <br /> l� zt '. FSHtfp1ttdJ � II•ttHJ kNtg7Rt : <br /> 1111 A Heating 14:18 18:37 259 <br /> Ur Passed $ <br /> T� A Keep Warm 18:37 19:37 60 r�-t ted, • <br /> f Pre Vacuum 19:37 19:50 13 []u Hold <br /> fg- If Keep Pressure 19:50 20:20 30 <br /> 1111 Humidifying 20:20 21:03 43 Injector i> -A-9- Operator <br /> jlG EO injection 21:03 21:23 20 M <br /> EO Manger7EAI* <br /> k EO Exposure 21:23 05:23 480 <br /> Aeration 05:23 05:51 28 Mirco Lab Manger,%* <br /> J K Flushing 05:51 06:21 30 QA Managert !t -W <br />