My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1975-2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
1420
>
4500 - Medical Waste Program
>
PR0450009
>
COMPLIANCE INFO_1975-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2022 12:55:09 PM
Creation date
7/3/2020 10:18:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4500 - Medical Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1975-2013
RECORD_ID
PR0450009
PE
4522
FACILITY_ID
FA0002562
FACILITY_NAME
Sutter Valley Hospitals dba Sutter Tracy Community Hospital
STREET_NUMBER
1420
Direction
N
STREET_NAME
TRACY
STREET_TYPE
Blvd
City
Tracy
Zip
95376
APN
233-081-01
CURRENT_STATUS
01
SITE_LOCATION
1420 N Tracy Blvd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\MW\MW_4522_PR0450009_1420 N TRACY_1975-2015tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. Place Biological indicator test packs in autoclave bag with red bag trash and tie off the bag. <br /> 4. Pressure gauge on San-l-Pak/sterilizer must be checked and recorded before proceeding with the <br /> process. Pressure gauge reading should be above 72psi. San-I-Pak sterilizer recordings of <br /> temperature and pressure will be stored in EVS and kept for a minimum of three years. <br /> I <br /> 5. At the completion of sterilization cycle, biological indicator test indicator is taken to the in hospital <br /> Laboratory for incubation and results recorded in a 3MTM log book also located in the STCH <br /> Laboratory. Log is kept for three years <br /> 6. Incubation time for control test is 3 to 5 hours before reading and documented. <br /> 7. Control has to be kept for 24 hours after the test is completed for visual validation. <br /> B. Listing of specific materials needed for procedure <br /> I <br /> 1. Control sample(unsterilized indicator) <br /> 2. Actual biological indicator(placed in sterilizer) <br /> 3. 3M Attest TM Rapid Biological indicator log book <br /> i <br /> 4. 3M Attest TM Rapid Biological indicator incubator <br /> i <br /> i <br /> i A. Sources <br /> 1. National Standards and Recommended Practices for Sterilization.Association for the Advancement <br /> of Medical Instrumentation,Arlington,Virginia,Vol 1.1-1.2,1995. <br /> 2. CDC Control and prevention, Sterilization—Monitoring, March 4,2010 http://w�nNv„cdc.gOv/ <br /> oralhealth/infectioncontrol/fag/sterilization monitorina.htm <br /> 3. Waste Management Healthcare Solutions, Inc. <br /> 19966 Don Lee Place Ste. C <br /> Escondido, CA 92029 j <br /> i <br /> B. Reviewed and revised by Hawa Suah (author unknown); Judy Brown RN (interim OR manager) <br /> C. Related policies and procedures: <br /> 1. STCH PolicyStat Portal-> Environmental Services-> Disposition of Trash Procedure(ES.20.00.00) <br /> 2. Refer to EVS policies on PolicyStat j <br /> ATTACHMENTS <br /> A. None <br /> ,All revision dates: 4/1/2013 6/1/2012,4/10/2012,4/20/2010 <br /> tte_ ; No Attachments <br /> Biological Testing of Auto Clave,ES-81-35-05.Retrieved 12/27/2016.Official copy at http://sh-stch.policystat.com/policy/536373/. Page 2 of 2 <br /> Copyright 0 2016 Sutter Tracy Community Hospital <br />
The URL can be used to link to this page