My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1801
>
4500 - Medical Waste Program
>
PR0536198
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2024 12:30:01 PM
Creation date
7/3/2020 10:21:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4500 - Medical Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0536198
PE
4530
FACILITY_ID
FA0018391
FACILITY_NAME
SATELLITE DIALYSIS (STKN)
STREET_NUMBER
1801
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
1801 E MARCH LN BLDG A
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\MW\MW_4530_PR0536198_1801 E MARCH_.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MEDICAL WASTE INSPECTION REPORT <br /> Date : 10/4/2023 <br /> San Joaquin County Environmental Health Department Program <br /> 1868 E . Hazelton Ave . , Stockton , CA 95205 Record : PR0536198 <br /> \ cP (209) 468-3420 Program <br /> www.siogv. org/ehd Element : 4530 <br /> 11 � l , . � .� . . • , � _ II � i , � • i � / <br /> Specialist: Print: Stephanie Ramirez Signature : / 1 Phone : 209 -616-3069 <br /> i <br /> 23 . HSC 117630 - Biohazard bag shall meet the standards set forth in this section . <br /> (b ) The biohazard bag that is used to collect medical waste within a facility shall be manufacturer certified to meet the <br /> ASTM D1709 dart drop test, provided that when the bag is prepared for transport offsite , it is placed into a USDOT <br /> approved container lined with a biohazard bag that is ASTM D1709 and ASTM D1922 certified . <br /> OBSERVATION : Observed biohazardous containers (totes ) in the designated accumulation area have medical waste in <br /> biohazard bags , however the containers are not lined . <br /> CORRECTIVE ACTION : Line biohazardous containers with a biohazardous bag that is ASTM D1709 and ASTM D122 certified <br /> when preparing for transport offsite . <br /> 24. HSC 118275 - Medical , biohazardous , sharps , trace chemo , pathology, or pharmaceutical waste shall be segregated <br /> and contained pursuant to this section . The container shall be properly labeled . <br /> OBSERVATION : Pharmacuetical wastes are stored in containers that lack the words "incinerate only' on lid and all four sides of <br /> container . <br /> CORRECTIVE ACTION : Provide the words the words " incinerate only' on lid and all four sides of container . <br /> Notes : <br /> 1 . Report emailed to MistrettaJ (alsatellitehealth . com <br /> 2 . Barnett is the medical waste hauler. Pick up is 3 times per week . <br /> 3 . Staff is trained annually. <br /> 4 . Biohazard bags are ASTM D1709 and ASTM D1922 certified <br /> CORRECTIONS DUE BY OCTOBER 25 , 2023 <br /> Reinspection onlabout: A reinspection fee of $ 162 per hour may be charged . Page 2 of <br /> 2 <br /> EH -2/2023 <br />
The URL can be used to link to this page
Your browser does not support the video tag.