URS <br /> Mr. Robert McClellon <br /> April 30,2007 <br /> Page 2 <br /> extraction wells was less than 5 ppmV. Based on these results,there was a potential for VOC <br /> constituents to be present in groundwater.To assess the presence or absence of VOC constituents in the <br /> groundwater,three groundwater monitoring wells were installed at the site on June 12, 2006.Following <br /> installation of the groundwater monitoring wells, groundwater samples have been collected and analyzed <br /> quarterly for VOCs.The Regional Water Quality Control Board(RWQCB)requested that groundwater <br /> samples also be collected and analyzed for metals and general minerals beginning the fourth quarter of <br /> 2006. <br /> FIELD ACTIVITIES <br /> During the first quarter of 2007,the landfill gas concentrations were measured within the probes, <br /> extraction wells,and passive vents every two to three weeks. The quarterly groundwater monitoring <br /> activities were completed on March 14,2007. <br /> Each gas-migration monitoring probe,each extraction well,and each passive vent was measured for <br /> methane,oxygen,and carbon dioxide using a handheld portable landfill gas monitor.These <br /> measurements were recorded in a field log book. <br /> The groundwater samples were collected from the three monitoring wells using the following <br /> procedures: <br /> • The water level from each monitoring well was measured using an electronic water level <br /> sounder. <br /> • Prior to groundwater sample collection,each well was purged using a bailer. During <br /> purging,groundwater parameters (pH,temperature, and conductivity)were recorded on the <br /> Monitoring Well Sampling Log form(Attachment 1)at least once per well casing volume. <br /> Purging was completed when the groundwater parameters had stabilized to within 10 <br /> percent.The purged water was placed in 55-gallon drums. <br /> • A groundwater sample was collected from each well,using a bailer.The groundwater <br /> samples were placed into the analytical laboratory-prepared sample containers. <br /> • The groundwater samples were labeled and placed in an ice chest with ice. The samples was <br /> shipped to EMAX analytical laboratory in Torrance,California under proper chain-of- <br /> custody procedures for VOC analysis by U.S. Environmental Protection Agency(EPA) <br /> Method 8260B,dissolved metals(CAM 17)by EPA Method 6010/6020/7470,and total <br /> dissolved solids(TDS)by EPA Method 160.1. <br /> RESULTS <br /> Soil Vapor.Methane concentrations measured during the quarter in VW-1,VW-2, VW-3, VW-4, VW- <br /> 7S,VW-7D,VW-8S, VW-8D, VW-9, and VW-10 were all 0 percent. Methane concentrations for the <br /> remaining vapor probes ranged from 0%to 0.5%in VW-5S, from 0.4%to 1.0%in VW-5D, from 0.7% <br /> to 4.2% in VW-6S, and from 0.9%to 2.4% in VW-6D. <br />