My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1968-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNPIKE
>
3504
>
4400 - Solid Waste Program
>
PR0515730
>
COMPLIANCE INFO_1968-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:50:43 PM
Creation date
7/3/2020 10:38:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1968-2006
RECORD_ID
PR0515730
PE
4430 - SOLID WASTE CIA SITE
FACILITY_ID
FA0012310
FACILITY_NAME
WORLD ENTERPRISES
STREET_NUMBER
3504
Direction
S
STREET_NAME
TURNPIKE
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17517018
CURRENT_STATUS
Active, billable
SITE_LOCATION
S TURNPIKE RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4430_PR0515730_0 S TURNPIKE_1968-2006.tif
Site Address
3504 S TURNPIKE RD STOCKTON 95206
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
214
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Instruction Manual <br />0 6.1 Gas Sensor Module Locations <br />The gas sensor module is a diffusion type sensor <br />that should be located close to the anticipated source <br />or destination of the gas hazard. For heavy gases <br />such as H 2 S install the module within 24 inches of <br />the ground. For lighter gases such as CO and com- <br />bustible gases use a higher elevation. <br />After optimum locations are determined based on <br />the above recommendations, consideration should <br />be given to placing the sensors in locations that are <br />accessible for calibration service. Slight adjustments <br />to the location of the sensor may have little impact <br />on effectivity but major effect on accessibility. <br />y. <br />1. Model 20X Series <br />Where possible sensor modules should be installed <br />with the sensor facing vertically down. The lid of the <br />sensor module should face out for easy access. <br />Sensors may be mounted directly onto the end of a <br />vertical conduit, or bracketed to a vertical surface <br />using the two mounting flanges. Insure that the body <br />of the enclosure is at least 1" from the wall so that <br />the sensor assembly can be rotated for removal and <br />replacement. <br />2. Model 20OX Series <br />Where possible sensor modules should be installed <br />on a vertical surface. The module can be mounted <br />either using screws through the mounting flanges or <br />using an adhesive tape provided with the unit. <br />These modules are intended for use with the plug-in <br />AC/DC power supply shipped connected to the unit. <br />The module should be mounted in an area conve- <br />nient for the plug-in power supply. The power sup- <br />ply is removed if connecting the module to a Sierra <br />Monitor Alarm Panel. If the power supply provided <br />by Sierra Monitor is not used, user must employ <br />any wiring methods according to the US NEC and <br />the Canadian CEC and Class 2 power source re- <br />quirements. <br />6.3 Wiring <br />For installations where the distance from the con- <br />troller to the sensor is greater than 500 feet, 18 <br />AWG cable is recommended. <br />The terminal strip on the electronics board in the <br />module. The wiring must be connected as indicated <br />in Figure 6.1 depending upon the controller or relay <br />configuration being used. <br />6.4 Power Supply <br />The power supplied by the controlling device or an <br />external power supply must meet the following speci- <br />fications: <br />Voltage: 9 - 24 VDC (It must be a <br />Listed/Certified Class 2 <br />output power source. <br />Current: 250 mA <br />The Model 20OX Series includes a plug-in AC/DC <br />power supply. <br />Terminal <br />Function <br />T131-1 <br />+ VDC 9 — 24 <br />T131-2 <br />GND OVDC <br />TB2-1 <br />Relay NC (Normally Closed) or <br />Out ut to Model 2102 Safe <br />TB2-2 <br />Relay Common <br />T132-3 <br />Relay NO (Normally Open) or <br />Output to Model 2102 Alarm <br />Table 6.1 <br />Interconnect wiring from the controller to the module <br />is by 4 conductor 22 AWG (or lower AWG) cable, <br />conduit as necessary. Shielding is not required. <br />Page: 9 20X/20OX Gas Sensor Modules (08/04) <br />
The URL can be used to link to this page
Your browser does not support the video tag.