My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SPRECKELS
>
18800
>
4400 - Solid Waste Program
>
PR0519122
>
COMPLIANCE INFO_1997-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2021 1:20:28 PM
Creation date
7/3/2020 10:38:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2008
RECORD_ID
PR0519122
PE
4430
FACILITY_ID
FA0007439
FACILITY_NAME
SPRECKELS SUGAR PLANT #2
STREET_NUMBER
18800
STREET_NAME
SPRECKELS
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
SEE COMMENTS
CURRENT_STATUS
02
SITE_LOCATION
18800 SPRECKELS RD
P_LOCATION
04
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4430_PR0519122_18800 SPRECKELS_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
206
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I\ <br /> KLEBNFELDER <br /> File No. 20-3978-01.W10 <br /> July 26, 1997 <br /> 5. A copy of this report should be submitted to PHS/EHD and the RWQCB for their <br /> consideration. Furthermore, a letter of"no further action"should be requested from both <br /> agencies for the areas which are the subject of this report. <br /> 4.11 AST Locations (File No. 20-3978-01.W12) <br /> Based on the results of the subsurface assessment conducted in this area, Kleinfelder had the <br /> following recommendations detailed in our report "Limited Phase II Soil and Groundwater <br /> Assessment, Existing and Former Above-Ground Storage Tank Locations, (Phase I ESA <br /> Recommendation 12), Former Spreckels Sugar Plant No. 2, 18800 South Spreckels Road, <br /> Manteca, California(APN#221-180-04)"dated February 24, 1997: <br /> 1. The existing soil cuttings (a.k.a. drilling returns) should be evaluated and properly <br /> disposed of by Atherton-Kirk.. Kleinfelder can assist the Atherton-Kirk in that disposal <br /> at the Client's request at an additional cost. <br /> 2. The equipment rinseate should be properly evaluated and disposed of by Atherton-Kirk. <br /> Kleinfelder can assist Atherton-Kirk in that disposal at the Client's request at an <br /> additional cost. <br /> 3. If discolored soil, odors, or other evidence of contamination are encountered during site <br /> grading, development, etc., our office should be notified immediately. <br /> 4. Kleinfelder does not recommend further assessment at the following existing/former above <br /> ground tank locations at the former Spreckels Sugar Plant No. 2: <br /> • Acid/Caustic/Sulfuric Acid Storage Area <br /> • North Sulfuric Acid Tank <br /> • Hydrochloric Acid Tank <br /> • Fuel Oil Storage Tank, Pump Station and Product Lines <br /> • Waste Oil Tank and Drum Storage Area <br /> • Spreckels Gasoline Convault <br /> A copy of this report should be submitted to the San Joaquin County Public Health Services <br /> Department (PHS/EHD) and the Regional Water Quality Control Board (RWQCB) for their <br /> consideration. Additionally, Kleinfelder recommends that a letter of"no further action" be <br /> requested from both agencies the above ground tank locations described above. <br /> 20-3978-01.W10/2017L155 Page 27 of 50 Copyright 1997,Kleinfelder,Inc. <br />
The URL can be used to link to this page