My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
COMPLIANCE INFO_1996-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2021 8:55:58 AM
Creation date
7/3/2020 10:39:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2003
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1996-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
623
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUIREMENTS <br /> FOR CITY OF STOCKTON -10- <br /> AUSTIN ROAD LANDFILL FACILITY <br /> CLASS III LANDFILL <br /> SAN JOAQUIN COUNTY <br /> 15. All new containment systems shall: include a composite liner which consists of an <br /> upper synthetic flexible membrane component"(synthetic liner or SL) and a lower <br /> component of soil. The SL shall be at least 40-mils thick(or at least 60-mils thick if <br /> high density polyethylene) and shall be installed in direct and uniform contact with the <br /> underlying compacted soil component. The lower component shall be compacted soil <br /> that is at least two feet thick and that has an hydraulic conductivity of no more than 1 <br /> X 10'cm/sec(this specification is referred to as the Prescriptive Design). For landfill <br /> covers where clay is compacted over refuse, a hydraulic conductivity of 1 x 101 <br /> cm/sec may be substituted for the 1 x 10''cm/sec requirement. <br /> 17. New landfill units and lateral expansions shall not be located in wetlands unless the <br /> Discharger has successfully completed, and the Board has approved, all <br /> demonstrations required for such discharge under 40 CFR 258.12(a). <br /> 18. Landfill leachate shall be disposed of by a Board-approved method. <br /> Surface Impoundment Specifications <br /> 19. Design and constriction plans and specifications, including a construction quality <br /> assurance program, shall be submitted to Board staff for approval before construction <br /> of any surface impoundment. After surface impoundment construction, a <br /> construction quality assurance report shall be submitted to the Board and approved <br /> by Board staff'prior tb bppration of the surface impoundment. <br /> Landfill Closure Specifications <br /> 20. At closure, the unlined modules shall receive a final cover consisting, at a minimum, <br /> of a two-foot tick 1fo&ditidh layer which may contain waste materials, overlain by a <br /> one-foot thick clay,liner, and finally by a one-foot thick vegetative soil layer, or an <br /> engineered equivdht fi�iat cover;approved by the Board pursuant to Subsections <br /> 2510 ' ` � - - <br /> (b) and'(c) of'Lhapter 15. Lined landfill modules, or portions thereof, shall be <br /> covered with a barrier layer having a permeability at least as low as the liner. <br /> 21. Vegetation shall be planted and maintained over each closed landfill unit. Vegetation <br /> shall be selected to require a minimum of irrigation and maintenance and shall have a <br /> rooting depth not in excess of the vegetative layer thickness. <br /> 22. Closed landfill units shall be graded to at least a three percent grade and maintained <br /> to prevent ponding. <br />
The URL can be used to link to this page
Your browser does not support the video tag.