Laserfiche WebLink
Monitoring Report Compliance C list <br /> Discharges Regulated by Title 27 and/or Part 258 <br /> Rf47QCB <br /> Reference Parameter Yes No N/A Revie`ver Comment <br /> WDRs/MRP/ Groundwater Monitoring <br /> Standard <br /> Provisions 1. Are all groundwater Field Parameters X <br /> (Sept 93/Aug 97) Monitoring Parameter, and CDCs <br /> (if required) samples and analyzed? <br /> in. Have any groundwater concentration X VOCs have been detected in <br /> limits been exceeded? If yes, identify MW-1,-4, -5, -10, -11, -13, &- <br /> in comments. 14. Inorganics elevated in MW- <br /> 3 &-4 <br /> n. Is there a description and graphical X <br /> presentation of groundwater flow <br /> direction and gradient? <br /> o. Monitoring Wells: Is there a X <br /> description,method,and time <br /> of water level measurement and <br /> well recovery time? <br /> p. Purging: Is there a description X <br /> of the purging method,purge <br /> pump and its placement, and <br /> field parameters? <br /> Additional Comments and Recommendations: <br /> This site has an active groundwater treatment facility since 1994, as part of a corrective action program. The <br /> current treatment system has failed to contain or cleanup the contaminant plume. Work has begun on a new <br /> corrective action plan to capture the entire plume and clean up groundwater. It is likely that landfill gas is a <br /> continuing source of VOCs to groundwater at this site. <br /> RWQCB Staff Signature: <br /> Date: �v <br />