My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
COMPLIANCE INFO_1996-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2021 8:55:58 AM
Creation date
7/3/2020 10:39:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2003
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1996-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
623
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUIREMENTS ORDER NO. R5-2003-0049 -18- <br /> FORWARD INC. AND ALLIED WASTE INDUSTRIES <br /> FOR OPERATION OF <br /> FORWARD CLASS II LANDFILL <br /> SAN JOAQUIN COUNTY <br /> 5. Construction shall proceed only after all applicable construction quality assurance plans <br /> have been approved by Executive Officer. <br /> 6. Following the completion of construction of a Unit or portion of a Unit, and prior to <br /> discharge onto the newly constructed liner system, the final documentation required in <br /> §20324(d)(1)(C) of Title 27 shall be submitted to the Executive Officer for review and <br /> approval. The report shall be certified by a registered civil engineer or a certified <br /> engineering geologist. It shall contain sufficient information and test results to verify that <br /> construction was in accordance with the design plans and specifications, and with the <br /> prescriptive standards and performance goals of Title 27. Testing shall include a liner <br /> leak detection test conducted after installation of the drainage layer and the operations <br /> layer. <br /> 7. A third party independent of both the Discharger and the construction contractor shall <br /> perform all of the construction quality assurance monitoring and testing during the <br /> construction of a liner system. <br /> 8. If monitoring reveals substantial or progressive increases of leachate generation above the <br /> design leachate flow volume by the Unit or portion of the Unit, such that the depth of <br /> fluid on any portion of the LCRS (excluding the leachate removal pump sump) exceeds <br /> 30 cm,the Discharger shall immediately notify the Board in writing within seven days. <br /> The notification shall include a timetable for remedial or corrective action necessary to <br /> achieve compliance with the leachate depth limitation. <br /> 9. Any WMU that will not receive waste over the winter rainy season(November 1 through <br /> March 30) shall be graded to shed stormwater(at least a 3% grade), maintained to prevent <br /> ponding and have an enhanced intermediate cover installed. The enhanced intermediate <br /> cover shall consists of. one foot of clayey soil compacted to achieve a hydraulic <br /> conductivity of 10-5 cm/sec or some other equivalent hydraulic barrier overlain by an <br /> erosion layer composed of one foot of loosely compacted soil. <br /> 10. Closed landfill modules shall be graded to at least a three-percent(3%) grade and <br /> maintained to prevent ponding. <br /> E. DETECTION MONITORING SPECIFICATIONS <br /> 1. The Discharger shall comply with the detection monitoring program provisions of Title <br /> 27 for groundwater, surface water, soil-pore gas, and the unsaturated zone, and in <br /> accordance with Monitoring and Reporting Program No. R5-2003-0049. <br /> 2. The Discharger shall provide Board staff a minimum of one week notification prior to <br /> commencing any field activities related to the installation,repair, or abandonment of <br />
The URL can be used to link to this page
Your browser does not support the video tag.