My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
COMPLIANCE INFO_1996-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2021 8:55:58 AM
Creation date
7/3/2020 10:39:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2003
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1996-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
623
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Mustin Road Landfill <br /> Landfill Ga_ , ration and Control Evaluation <br /> Camp Dresser&McKee Inc. (CDM),in conjunction with staff from Ogden Power,performed a <br /> complete monitoring of the gas extraction system and perimeter probes on the north side of the <br /> landfill on June 30, 1998. All extraction wells currently on-line were monitored for methane <br /> concentration,static well vacuum, and flow. The extraction well monitoring results are tabulated in <br /> Table 1. Similar data was collected from locations throughout the header system and at the energy <br /> recovery station and are presented in Table 2. As shown on Table 3,soil gas probes SGP9 through <br /> SGP14 were also monitored for pressure and methane. <br /> Table 1 <br /> Extraction Well Field Data <br /> Austin Road Landfill, Stockton, California <br /> 6/30/98 <br /> Well d-pressure Calculated Well Vacuum Header Vacuum CH4 Status Comments <br /> ID (in-water) Flow(cfm) (in-water) (in-water) (%) <br /> 1 0.04 11 -1.06 -1.22 54.0 50%open <br /> 2 0.07 15 -2.46 -2.85 56.5 20%open <br /> 6 0.09 17 -2.03 -3.16 57.0 30%open <br /> 15 0.02 8 -0.82 -3.36 57.0 10%open <br /> 16 0.04 11 -0.12 -3.34 57.0 15%open <br /> 20 0.00 0 0.49 .-3.41 53.0 closed could not get negative <br /> well vacuum reading <br /> 21 0.04 11 0.50 -3.40 55.0 10%open could not get negative <br /> well vacuum reading <br /> 26 0.03 10 -0.08 -3.24 54.0 10%open <br /> 29 0.02 8 -2.46 no port 58.2 open <br /> 30 0.00 0 -0.03 no port 53.5 1 closed <br /> 31 0.06 14 -0.26 -2.76 51.0 15%open <br /> 33 0.00 0 -0.12 no port 50.7 closed <br /> 34 -0.35 na -0.30 no port 51.5 20%open could not get positive <br /> pressure reading <br /> 35 0.00 0 0.03 no port 58.5 closed <br /> 36 1 0.03 10 -0.64 no port 58.9 10%open <br /> 37 0.04 11 -0.76 no port 48.5 30%open <br /> 38 0.02 8 -0.35 no port 54.2 10%open <br /> 39 0.05 13 -0.71 no port 52.0 90%open <br /> 40 0.00 0 -0.22 no port 46.0 closed <br /> 41 0.03 10 -0.62 -0.69 58.0 open <br /> 42 0.01 6 -0.70 -0.71 61.8 open <br /> 43 0.08 16 -0.50 -0.70 61.0 open <br /> 44 0.13 21 -0.35 -0.59 60.0 open <br /> 46 0.02 8 -0.61 -0.62 60.5 open <br /> 47 0.07 15 -0.46 -0.62 62.5 open <br /> 48 0.02 8 -0.63 -0.65 59.3 open <br /> 49 0.09 17 -0.45 -0.61 62.0 open <br /> 50 0.00 0 -0.17 no port 50.7 10%open <br /> 51 0.06 14 -0.59 no port 57.9 open <br /> Totalized Flow=260 cfm <br /> CDM Camp Dresser&McKee 2 <br /> w9W50Qt01 s <br />
The URL can be used to link to this page
Your browser does not support the video tag.