Laserfiche WebLink
c <br /> RDSI MATRIX <br /> RDSI SECTION REG.CITATION RESPONSE REFERENCE <br /> proper grading and elimination of stagnant ponds, <br /> noise-makers and wind-agitated,reflective tape for bird <br /> control. <br /> Based on the current performance of bird control Appendix G, <br /> measures at the landfill and the proposed mitigation and Stockton <br /> monitoring program,the Stockton Metropolitan Airport Metropolitan <br /> administration does not foresee any additional safety Airport Letter <br /> hazards or conflicts for the airport. (See Stockton <br /> Metropolitan Airport comment letter attached as <br /> Appendix G). <br /> FAA concerns about birds may necessitate bird count <br /> records. <br /> VI.G. DRAINAGE AND EROSION CONTROL <br /> 14 CCR 17708 Erosion control measures include maximum slope of 4:1, Appendix I,FDSR <br /> matting and silt fences,phased and partial coverage,and Sec. 1.5.7,Pages 1-19 <br /> maintenance of vegetative cover. to 1-20; FDSR Sect. <br /> Surface water control systems to handle 100-year,24- 1.6,Pages 1-20 to 1- <br /> hour precipitation event. 28; FDSR App. D <br /> Appendix B„CEP <br /> Dwg.Pl,CEP Dwg. <br /> P7,Details 1 and 3 <br /> VI.H. LITTER CONTROL <br /> 14 CCR 17711 Compaction and prompt coverage of the refuse. Orient Appendix I,FDSR <br /> 14 CCR 17683 the working face on the downwind side of prevailing Sec. 2.2.2,Page 2-16 <br /> winds. Litter and debris pick-up as necessary.Litter <br /> control fences. <br /> VI.I. NOISE CONTROL <br /> 14 CCR 17712 Operate only during permitted hours.Maintain buffer Appendix I,FDSR <br /> zone.Periodic noise measurements at the boundaries. Sec. 2.2.2,Page 2-17 <br /> 0:VNGHAM\ML1059.D0C 111131% R.W.Beck 2-23 <br />