Laserfiche WebLink
Section No: 6 <br />Page: 16 of 16 <br />Revision No: 2.0 <br />Date: January 15, 1994 <br />Sampling Procedures <br />TABLE 6-1 RECOMMENDEDS LE COLLECTION AND PRESERVATION <br />Volume Holding <br />Analysis C4,er LML Preservation Time <br />Hazardous Waste Characterization <br />Corrosivity <br />P,G <br />100 <br />Cool, 4 C <br />7 days <br />Ignitabiliity <br />G <br />100 <br />Cool, 4 C <br />7 days <br />-lined cap <br />Reactivity/ <br />G <br />100 <br />Cool, 4 C <br />7 days <br />Reactions <br />-lined cap <br />Sulfide/Sulfide <br />G <br />100 <br />Cool, 4 C <br />7 days <br />generation <br />-lined cap <br />TTLC, STLC, TCLP, and EP Toxicity <br />Metals <br />G <br />Soo <br />Cool, 4 C <br />30 days <br />TFE-lined cap <br />Pesticides <br />G, amber <br />1000 <br />Cool, 4 C <br />7 days* <br />TFE-lined cap <br />Herbicides <br />G, amber <br />1000 <br />Cool, 4 C <br />7 days* <br />TFE-lined cap <br />Bioassays <br />Chronic P,G 3x1000 Cool, 4 C 24 hr. <br />Acute P,G 2x5 gal Cool, 4 C 24 hr. <br />•- Note: All solid samples should be collected in stainless steel sleeves, brass sleeves or in glass <br />jars all with teflon -lined caps and oz. capacity. All solid samples should be kept cool at 4 <br />C. <br />