Laserfiche WebLink
F-1 <br />Section No: 12 <br />Page: I of 21 <br />Revision No: 2.0 <br />Date: January 15, 1994 <br />Performance and System Audits <br />The Quality Assurance Director or Officer is responsible for internal system audits, <br />coordinating all external audits and performance evaluation (PE) samples. In addition, the <br />QA Director o•r Officer is responsible for maintaining state and agency certcation. <br />12.1 System Audits <br />System audits are performed both by external agencies, and by the laboratory Quality <br />Assurance group. The focus of these audits is the overall analytical "system", from login <br />to delivery of the finished reports. The purpose of the audit is to document compliance <br />with the specified methodology contained in our Standard Operating Procedures (SOPs). <br />12.1.1 Internal System Audit Program <br />Internal system audits are conducted on a monthly basis. Several analytical methods are <br />selected each month for a systems audit. Compliance with all the required OC is <br />evaluated and indicated on the QA inspection summary report form (figure 16-1). This <br />report contains all the new nonconformance items, previously uncompleted <br />non-conformance it and finally all non-conformance items completed. Dates are <br />recorded when the non-conformance was found and when it was completed. This report <br />is given to all supervisors and managers. With these steps an ongoing quantitative <br />assessment of the analytical system is provided. <br />12.1.2 External System Audits <br />System audits are performed by outside government agencies such as the California <br />Department of Health Services, Lawrence Livermore National Laboratory and the Army <br />Corp of Engineers. Audits are also performed by private agencies such as Chemical <br />Waste Manageinent, Inc. <br />12.2 Performance Evaluation Samples <br />Performance evaluation audits are used to provide a direct evaluation of the ability of the <br />analytical systems to generate data that is consistent with the laboratory's stated <br />objectives for accuracy and precision. External PEsamples are analyzed as part of the <br />certification and approval process for various state and federal agencies, as well as for <br />other organizations. <br />12.2.1 External Performance Evaluation Samples <br />Performance evaluation samples are analyzed for a number of outside agencies I <br />including: <br />(1) USEPA semi-annual drinking water check samples (WS series) <br />(2) USEPA semi-annual wastewater check samples (WP series) <br />(3) USEPA annual wastewater check samples (DMR studies) <br />(4) EMSL, Las Vegas, radiochemistry check samples <br />(5) Environmental Research Associates check samples <br />12.3 Certifications, Accreditations and Agency Approvals <br />FGL Environmental participates in laboratory certification programs with California, and <br />other states. A copy of the California Environmental Laboratory Accredititation Program <br />(ELAP) approved analyses list may be found in Figures 12-3 and 12-4. A copy of the <br />Nevada Department of Human Resources approved analyses list may be found in Figure <br />12-5. <br />